Evidence map›Paper›PMID 39445421›Full record

ArticleClinical cardiology2024

Pacemaker Implantation for Low-Grade Conduction Abnormalities After Balloon-Expandable Transcatheter Aortic Valve Implantation.

Julian Wolfes, Fernando de Torres Alba, Gerrit Kaleschke, Julia Vormbrock, Florian Reinke, Christian Ellermann, Helmut Baumgartner, Lars Eckardt, Gerrit Frommeyer

Abstract read
In one paragraph

Article in Clinical cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Julian WolfesDepartment of Cardiology II-Electrophysiology, University Hospital Münster, Münster, Germany.ORCID http://orcid.org/0000-0002-9344-7826
Fernando de Torres AlbaDepartment of Cardiology III-Adult Congenital and Valvular Heart Disease, University Hospital Münster, Münster, Germany.
Gerrit KaleschkeDepartment of Cardiology III-Adult Congenital and Valvular Heart Disease, University Hospital Münster, Münster, Germany.
Julia VormbrockDepartment of Cardiology III-Adult Congenital and Valvular Heart Disease, University Hospital Münster, Münster, Germany.
Florian ReinkeDepartment of Cardiology II-Electrophysiology, University Hospital Münster, Münster, Germany.
Christian EllermannDepartment of Cardiology II-Electrophysiology, University Hospital Münster, Münster, Germany.
Helmut BaumgartnerDepartment of Cardiology III-Adult Congenital and Valvular Heart Disease, University Hospital Münster, Münster, Germany.
Lars EckardtDepartment of Cardiology II-Electrophysiology, University Hospital Münster, Münster, Germany.
Gerrit FrommeyerDepartment of Cardiology II-Electrophysiology, University Hospital Münster, Münster, Germany.ORCID http://orcid.org/0000-0002-1431-9886

Funding

The authors received no specific funding for this work.
6 · The paper itself

Abstract

introductionA frequent complication after TAVI are postinterventional conduction abnormalities requiring permanent pacemaker implantation. In this study, we analyzed the characteristics of borderline conduction abnormalities leading to pacemaker implantation and the resulting ventricular pacing amounts. METHODS AND

resultsAll patients who underwent balloon-expandable TAVI between 2014 and 2019 in our tertiary center were analyzed in a retrospective manner. One hundred and sixty-five patients of 1083 TAVI-patients developed postinterventional conduction abnormalities leading to pacemaker implantation. Of these 19 (11.5%) did not represent a clear indication for cardiac pacing according to current European guidelines. Patient characteristics, underlying conduction abnormalities, and the temporal change of ventricular pacing percentages at 24 h and 6 weeks after pacemaker implantation were analyzed. The dominating borderline conduction abnormalities leading to pacemaker implantation were new-onset persisting bundle-branch-blocks and new first-degree AV-blocks with progression of AV-delay. While pacemaker implantation was safe and without severe complications in all cases, only 6 of 19 patients had high pacing amounts (95%-100%) after 24 h while 11 patients had low to no pacing amounts (0%-5%). After 6 weeks, 8 patients showed decreasing pacing amounts, no patient had an increasing amount of ventricular pacing and all patients had an intrinsic ventricular rhythm > 30/min.

conclusionIn our cohort of 1038 TAVI patients, 19 patients underwent PMI for borderline CAs (11.5% of all PMI). Of these, only 2 patients had high pacing amounts after 6 weeks. The risk of complete persisting heart block in these patients is very low. Furthermore, algorithms to reduce ventricular pacing are highly effective to avoid ventricular pacing whenever reasonable.

Indexed as

Aortic Valve StenosisPacemaker, ArtificialTranscatheter Aortic Valve ReplacementAgedAged, 80 and overAortic ValveArrhythmias, CardiacCardiac Pacing, ArtificialElectrocardiographyFemaleFollow-Up StudiesHeart Conduction SystemHumansMalePostoperative ComplicationsRetrospective Studieslow grade conduction disorderspacemaker indicationTAVR

Identifiers

PMID39445421
PMCPMC11499707

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.