ArticleCureus2024
A Rare Case of Shunt Malfunction Due to the Needle Guard Coming Off During Ventriculoperitoneal Shunt Surgery.
Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We report a rare case of shunt valve failure due to obstruction during ventriculoperitoneal (VP) shunt surgery for hydrocephalus after subarachnoid hemorrhage due to aneurysm rupture. The hydrocephalus shunt surgery was started normally, and there was no bending or twisting of the valve, nor blood contamination. However, after irrigation of the shunt valve, the shunt valve obstructed and malfunctioned before catheter connection and insertion into the subcutaneous space. Shunt valves are rarely damaged during surgery. In this case, the cause of the malfunction could not be identified during surgery, and it was necessary to use a shunt valve made by another company for patient safety. The surgery was completed without incident, but the cause of the obstruction, which was discovered after surgery, was that the needle guard inside the valve had come off from the bottom. The CODMAN CERTAS Plus Programmable Valve (CCPPV) in particular has excellent functionality, but the regular type needle guard is attached to the bottom of the valve pump. Therefore, it cannot withstand the handling during surgery that other valves tolerate. In the future, improvements in medical equipment and more careful operation of shunt valves by surgeons are required for risk management during surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.