Evidence map›Paper›PMID 39445044›Full record

ArticleCureus2024

Evaluation of the Conventional Acid-Etching System and the Self-Etching Primer in Bonding Metallic Orthodontic Brackets: An In-Vitro and In-Vivo Study.

Mohammed Hussin Alomar, Naji Massoud, Mohammad Y Hajeer, Hani Kharma, Doaa Hussain Jomah

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mohammed Hussin AlomarDepartment of Orthodontics, The National Dental Center for the Syrian Board and Specialization (NDC) Ministry of Health, Damascus, SYR.
Naji MassoudDepartment of Orthodontics, The National Dental Center for the Syrian Board and Specialization (NDC) Ministry of Health, Damascus, SYR.
Mohammad Y HajeerDepartment of Orthodontics, University of Damascus Faculty of Dentistry, Damascus, SYR.
Hani KharmaDepartment of Orthodontics, The National Dental Center for the Syrian Board and Specialization (NDC) Ministry of Health, Damascus, SYR.
Doaa Hussain JomahDepartment of Orthodontics, The National Dental Center for the Syrian Board and Specialization (NDC) Ministry of Health, Damascus, SYR.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aimed to compare the shear bond strength (SBS) of enamel-bonded orthodontic brackets with the conventional acid etching (CAE) system and the self-etching primer (SEP) in vitro and to compare the clinical performance of both systems when used in the treatment of malocclusion patients. MATERIALS AND

methodsIn the first part of the study, 40 extracted human premolars were randomly divided into two groups containing 20 teeth. The first group (the conventional enamel etching group) employed 37% phosphoric acid before bonding the metallic brackets (0.022-inch slot, MBT prescription, American Orthodontics, Sheboygan, WI, USA). The etching system was Tetric 5th (Ivoclar Vivadent, Schaan, Liechtenstein). The second group used a SEP (Sep Tetric 7th, Ivoclar Vivadent, Schaan, Liechtenstein) to bond the same brackets. In the first part of the study, SBS was evaluated, followed by the adhesive remnant index (ARI) assessment. The second part of the study (i.e., the clinical part) assessed a cohort of 30 patients during a 6-month observation period. The upper 10 teeth (from the second premolar on the right side to the second on the right side) were bonded using the chosen method for each patient in the clinical assessment. That is, 150 teeth in each group were evaluated regarding the failure rate. The ARI was assessed for those teeth that lost their brackets.

resultsThe mean SBS was greater in the SEP group compared to the CAE group (17.93 MPa and 16.60 MPa, respectively; P = 0.014). The difference was not statistically significant. Conversely, the failure rate was lower in the CAE group compared to the SEP group, with a failure rate of 6% and 14.7%, respectively. The difference was statistically significant (P = 0.014). However, the ARI showed no statistically significant difference in in-vivo and in-vitro analyses, as most bracket failures were at the adhesive level.

conclusionLaboratory results showed no statistical difference in the SBS mean values between the two groups. Clinically, the SEP group showed a greater failure rate than the CAE group, but both failure rates in the two groups were within the clinically acceptable range. The ARI did not show any difference between the two groups in terms of the failure site when the evaluation was conducted in vivo and in vitro, as most of the areas of failure were concentrated in the material itself.

Indexed as

adhesive remnant indexbonding strengthcompositeconventional acid etching techniquedebondingfailure ratemetallic bracketspremolarsself-etching primershear bond strength

Identifiers

PMID39445044
PMCPMC11498908

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.