ArticleJournal of synchrotron radiation2024
Green upgrading of SPring-8 to produce stable, ultrabrilliant hard X-ray beams.
Article in Journal of synchrotron radiation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- A high-energy X-ray beamline for materials science research at SPring-8: BL15XU.Journal of synchrotron radiation · 2026Article
- Sagittal collimating diaboloid: a new grazing-incidence mirror surface for higher-throughput resonant inelastic X-ray scattering spectrometers.Journal of synchrotron radiation · 2026Article
- Channel-cut monochromator withstanding incident powers above 400 W on undulator beamlines.Journal of synchrotron radiation · 2026Article
- The Impact of X-ray Damage in Chemical Crystalline Materials and New Opportunities for Small Molecule Serial Crystallography.Chemistry (Weinheim an der Bergstrasse, Germany) · 2025Review
- Conceptual design of the energy-switchable storage ring as a high-brilliance light source over a wide wavelength range.Journal of synchrotron radiation · 2025Article
- An X-ray beamline for utilizing intense, high-energy undulator radiation.Journal of synchrotron radiation · 2025Article
- Macromolecular crystallography for mammalian body temperature in support of molecular biophysics methods.Biophysical reviews · 2025Review
- Quantitative assessment of ohmic-type CdTe sensor response in a photon-counting X-ray imaging detector under continuous 12-49 keV irradiations.Journal of synchrotron radiation · 2025Article
- Ultimate brightness of a medium-energy synchrotron light source at operational beam intensity.Journal of synchrotron radiation · 2025Article
- Macromolecular crystallography at SPring-8 and SACLA.Journal of synchrotron radiation · 2025Article
- 30 years of Journal of Synchrotron Radiation and synchrotron science.Journal of synchrotron radiation · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
43 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
SPring-8-II is a major upgrade project of SPring-8 that was inaugurated in October 1997 as a third-generation synchrotron radiation light source. This upgrade project aims to achieve three goals simultaneously: achievement of excellent light source performance, refurbishment of aged systems, and significant reduction in power consumption for the entire facility. A small emittance of 50 pm rad will be achieved by (1) replacing the existing double-bend lattice structure with a five-bend achromat one, (2) lowering the stored beam energy from 8 to 6 GeV, (3) increasing the horizontal damping partition number from 1 to 1.3, and (4) enhancing horizontal radiation damping by installing damping wigglers in long straight sections. The use of short-period in-vacuum undulators allows ultrabrilliant X-rays to be provided while keeping a high-energy spectral range even at the reduced electron-beam energy of 6 GeV. To reduce power consumption, the dedicated, aged injector system has been shut down and the high-performance linear accelerator of SACLA, a compact X-ray free-electron laser (XFEL) facility, is used as the injector of the ring in a time-shared manner. This allows the simultaneous operation of XFEL experiments at SACLA and full/top-up injection of the electron beam into the ring. This paper overviews the concept of the SPring-8-II project, the system design of the light source and the details of the accelerator component design.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.