Evidence map›Paper›PMID 39443327›Full record

ArticleJournal of robotic surgery2024

Robotics can decrease the rate of post-operative ventral hernia: a single centre retrospective cohort study.

Vivekanand Sharma, Hesham Elkhwalka, Estelle Martin, Ramprasad Rajebhosale, Matthew Tutton, Subash P Vasudevan

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Vivekanand SharmaDepartment of Surgery, East Suffolk and North Essex NHS Foundation Trust, Colchester, UK. drvivekanandsharma@gmail.com.ORCID http://orcid.org/0000-0003-0985-8874
Hesham ElkhwalkaDepartment of Radiology, East Suffolk and North Essex NHS Foundation Trust, Colchester, UK.ORCID http://orcid.org/0009-0007-7071-1798
Estelle MartinDepartment of Surgery, East Suffolk and North Essex NHS Foundation Trust, Colchester, UK.ORCID http://orcid.org/0000-0002-6997-5872
Ramprasad RajebhosaleDepartment of Surgery, East Suffolk and North Essex NHS Foundation Trust, Colchester, UK.ORCID http://orcid.org/0000-0001-9089-7621
Matthew TuttonDepartment of Surgery, East Suffolk and North Essex NHS Foundation Trust, Colchester, UK.ORCID http://orcid.org/0000-0003-1191-2219
Subash P VasudevanDepartment of Surgery, East Suffolk and North Essex NHS Foundation Trust, Colchester, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Midline incision for extra-corporeal anastomosis is common with traditional laparoscopic right hemicolectomy. Incisional hernias develop in up to 20% of these patients within a year adding considerable morbidity and healthcare costs. Robotic assisted surgery (RAS) improves technical ease of intra-corporeal anastomosis, preventing midline extraction but its benefit over laparoscopy remains debated. We aimed to determine if robotic assisted surgery and Pfannenstiel extraction decreased the rate of radiologically detected incisional hernias compared to standard laparoscopy with extra-corporeal anastomosis. The secondary outcomes aimed to evaluate incidence of port site hernias in 8 mm robotic ports for which routine closure is not followed. Our single centre retrospective cohort study included patients who had minimally invasive right hemicolectomy and had cross-sectional imaging at least 1-year later. Patient demographics, body mass index, history of smoking or previous surgery was recorded. At imaging, evidence of new extraction site or port site-site hernia, contents and clinical impact was noted. A total of 100 patients (50 robotic and 50 laparoscopic) were included. Baseline characteristics appeared equally distributed. 16% (8 patients) who had laparoscopic surgery developed midline extraction site hernias which was significantly higher to RAS group (0 patients). 3 patients developed hernias at the site of robotic ports and this was more commonly at the right iliac fossa port. RAS, by simplifying intra-corporeal anastomosis has potential to eliminate incisional hernias, particularly when Pfannenstiel extraction is used. The potential for 8 mm robotic ports to develop clinically significant hernias cannot be ignored and meticulous closure can prevent patient harm.

Indexed as

ColectomyHernia, VentralLaparoscopyPostoperative ComplicationsRobotic Surgical ProceduresAgedAnastomosis, SurgicalCohort StudiesFemaleHumansIncisional HerniaMaleMiddle AgedRetrospective StudiesIncisional herniaLaparoscopic surgeryMinimally invasive colorectal surgeryRight hemicolectomyRobotic surgerySurgical outcomes

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.