ArticleMagnetic resonance imaging2025

Dual-tuned floating solenoid balun for multi-nuclear MRI and MRS.

Yijin Yang, Boqiao Zhang, Ming Lu, Xinqiang Yan

Abstract read
In one paragraph

Article in Magnetic resonance imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yijin YangDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN 37232, USA.
Boqiao ZhangDepartment of Electrical and Computer Engineering, University of Toronto, Toronto, ON M5S 1A1, Canada.
Ming LuVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN 37232, USA.
Xinqiang YanDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN 37232, USA; Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN 37232, USA. Electronic address: xinqiang.yan@vumc.org.

Funding

Upgrade and Refurbishment of a 7T MRI Scanner for ResearchS10OD030389 · OD · VANDERBILT UNIVERSITY MEDICAL CENTER · PI GORE, JOHN C · 2021 to 2021
$2.0M
Integrated Next-generation RF Transmit, Receive and B0 shimming coil system for brain and spinal cord MRI at 7 TeslaR01EB031078 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI YAN, XINQIANG · 2022 to 2025
$1.7M
Miniature and integrable balun for light-weight and flexible MRI RF coilsR03EB034366 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI YAN, XINQIANG · 2023 to 2024
$175k
NIBIB NIH HHS R01 EB031078NIBIB NIH HHS R03 EB034366NIH HHS S10 OD030389
6 · The paper itself

Abstract

Common-mode currents can degrade the RF coil performance and introduce potential safety hazards in MRI. Baluns are the standard method to suppress these undesired common-mode currents. Specifically, floating baluns are preferred in many applications because they are removable, allow post-installation adjustment and avoid direct soldering on the cable. However, floating baluns are typically bulky to achieve excellent common-mode suppression, taking up valuable space in the MRI bore. This is particularly severe for multi-nuclear MRI/MRS applications, as two RF systems exist. In this work, we present a novel dual-tuned floating balun that is fully removable, does not require any physical connection to the coaxial cable, and has a significantly reduced footprint. The floating design employs an inductive coupling between the cable solenoid and a floating solenoid resonator rather than a direct physical connection. Unlike the previous floating solenoid balun, this balun employs a two-layer design further to improve the mutual coupling between the two solenoids. A pole-insertion method is used to suppress common-mode currents at two user-selectable frequencies simultaneously. Bench testing of the fabricated device at 7 T demonstrated high common-mode rejection ratios at Larmor frequencies of both

Indexed as

Equipment DesignMagnetic Resonance ImagingMagnetic Resonance SpectroscopyPhantoms, ImagingHumansRadio WavesCable trapCommon-mode currentDual-tunedFloating balunMultinuclear MRI

Identifiers

PMID39442656
PMCPMC11955239

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.