ArticleCureus2024
Real-Time Dialysis Dose: Ionic Dialysis Versus Classical Urea Kinetic Modeling Indices.
Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Acute kidney injury after lung transplantation: prediction, prevention, and management.Renal failure · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction Worldwide, over 850 million people need renal replacement therapy, and over 80% of them are on hemodialysis. The term "dialysis adequacy" is most often associated with the achievement of minimally acceptable indices - single pool Kt/V (spKt/V) and urea reduction ratio (URR%) and largely does not take into account other clinical indicators in patients. In addition, it should be taken into account that in the conditions of clinical practice, their measurement is carried out according to standards controlled by the regulatory structures and is carried out with a frequency between one and three months, and not during each dialysis procedure. Accordingly, based on the obtained value, we assume that it refers to the urea clearance of the entire dialysis prescription. A new methodology for measuring dialysis adequacy through ionic dialysis allows dose estimation in real time without the need for additional blood tests by recording the difference in sodium ion conductivity at the dialyzer inlet and outlet. The latter corresponds to the dialysis dose delivered and can be measured at each dialysis session, enabling timely therapeutic intervention at minimal cost to the community. The aim of this original article is to present ion dialysis to the community as a reliable and inexpensive alternative to classical urea kinetic modeling (UKM), evaluating the comparability of the two methods and the possible sources of error in the result. Material and methods This was a retrospective study of 32 patients undergoing hemodialysis at the Clinic of Nephrology and Dialysis at the University Hospital St. Marina (Varna, Bulgaria) for the period between January and December 2020. For each of the patients, four measurements (every three months) of the delivered dialysis dose were performed by ion dialysis and classical urea kinetic modeling in order to assess the comparability and reliability of the two methods. Results The analysis of the results proved a high correlation between the validated indicators of dialysis adequacy (spKt/V; URR) and those registered with online monitoring (online clearance monitor) by ionic dialysis - online Kt/V (onKt/V) while at the same time reporting a significant difference in the two methods - primarily based on the anthropometric formulas used to estimate the volume. The established regression models confirmed the high predictive value of ionic dialysis in relation to the actually delivered dose. Discussion Despite the high bond strength, our recorded values for onKt/V are 8% lower compared to results using UKM. Therefore, onKt/V as an assessment metric has the ability to underestimate the dialysis dose received. Various factors as a possible source of error and its cause have been reported by some authors. Several studies have reported differences of 2-5% in instantaneous conductance measurements, which they associate mainly with differences in the diffusion coefficients of urea and sodium, as well as different effects of dialysis membrane charge or inadequate ultrafiltration correction. Conclusions Our study confirms that online clearance monitoring (OCM) is a practical non-invasive tool for daily use that complements the classic performance of OCM by helping to deliver an adequate dialysis dose with increased patient benefit and minimal cost of financial resources.