Evidence map›Paper›PMID 39438946›Full record

ArticleBMC oral health2024

Accuracy of robotic-assisted surgery for immediate implant placement in posterior teeth: a retrospective case series.

Tao Yang, Wenan Xu, Xiaojian Xing, Fengzhou Li, Shuo Yang, Buling Wu

Abstract read
In one paragraph

Article in BMC oral health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tao YangShenzhen Clinical College of Stomatology, School of Stomatology, Southern Medical University, Guangzhou, China.
Wenan XuShenzhen Clinical College of Stomatology, School of Stomatology, Southern Medical University, Guangzhou, China.
Xiaojian XingShenzhen Clinical College of Stomatology, School of Stomatology, Southern Medical University, Guangzhou, China.
Fengzhou LiShenzhen Clinical College of Stomatology, School of Stomatology, Southern Medical University, Guangzhou, China.
Shuo YangCenter of Oral Implantology, Stomatological Hospital of Southern Medical University, No.366, Jiangnan Avenue, Haizhu District, Guangzhou, Guangdong, 510280, China. alex2005191007@smu.edu.cn.ORCID http://orcid.org/0000-0003-2792-4708
Buling WuShenzhen Clinical College of Stomatology, School of Stomatology, Southern Medical University, Guangzhou, China. bulingwu@smu.edu.cn.ORCID http://orcid.org/0000-0002-9678-6962

Funding

Shenzhen Science and Technology Program JCYJ20220530162408020the President Foundation of Shenzhen Stomatology Hospital(Pingshan), Southern Medical University 2022A001the President Foundation of Shenzhen Stomatology Hospital(Pingshan), Southern Medical University 2022C003
6 · The paper itself

Abstract

backgroundRobotic computer-assisted implant surgery (r-CAIS) is a revolutionary innovation in oral implantation; however, the clinical feasibility of r-CAIS for immediate implant placement (IIP) in posterior teeth has not been verified. Thus, this study aimed to evaluate the accuracy of r-CAIS for IIP in posterior tooth regions.

methodsPatients with posterior teeth to be extracted and indicated to undergo r-CAIS were evaluated. The patients had positioning markers installed in the oral cavity and underwent cone-beam computed tomography (CBCT). Subsequently, minimally invasive tooth extractions were performed, and an individualised surgical plan was generated in the robotic software. After marker registration, implantation surgery was performed by the robotic arm under the supervision and assistance of the surgeons. Finally, the deviations between the planned and placed implants were evaluated based on preoperative and postoperative CBCT data.

resultsA total of 12 patients were evaluated. No adverse events occurred during the surgery. The mean global coronal, global apical, and angular deviations were 0.46 ± 0.15 mm (95%CI:0.36 to 0.56 mm), 0.46 ± 0.14 mm (95%CI:0.37 to 0.54 mm), and 1.05 ± 0.55° (0.69 to 1.40°), respectively.

conclusionsUnder the limited conditions of this study, the r-CAIS exhibited high accuracy in posterior teeth IIP surgery. Further multicentre randomised controlled studies are required to confirm the feasibility of this technology.

Indexed as

Cone-Beam Computed TomographyRobotic Surgical ProceduresAdultAgedDental Implantation, EndosseousFemaleHumansImmediate Dental Implant LoadingMaleMiddle AgedMolarRetrospective StudiesSurgery, Computer-AssistedAccuracyComputer-assistedImmediate implant placementPosterior teethRobotic surgical procedures

Identifiers

PMID39438946
PMCPMC11494748

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.