Evidence map›Paper›PMID 39435570›Full record

ArticleMagnetic resonance in medicine2025

Two-parametric prescan calibration of gradient-induced sampling errors for rosette MRI.

Peter Latta, Radovan Jiřík, Jiří Vitouš, Ondřej Macíček, Lubomír Vojtíšek, Ivan Rektor, Michal Standara, Jan Křístek, Zenon Starčuk

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Peter LattaCentral European Institute of Technology, Masaryk University, Brno, Czech Republic.ORCID 0000-0002-0579-8635
Radovan JiříkInstitute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic.ORCID 0000-0003-2555-9428
Jiří VitoušInstitute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic.ORCID 0000-0002-9183-8794
Ondřej MacíčekInstitute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic.ORCID 0000-0002-0179-5779
Lubomír VojtíšekCentral European Institute of Technology, Masaryk University, Brno, Czech Republic.
Ivan RektorCentral European Institute of Technology, Masaryk University, Brno, Czech Republic.
Michal StandaraDepartment of Radiology, Masaryk Memorial Cancer Institute, Brno, Czech Republic.
Jan KřístekDepartment of Radiology, Masaryk Memorial Cancer Institute, Brno, Czech Republic.
Zenon StarčukInstitute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic.ORCID 0000-0002-1218-0585

Funding

Czech Science Foundation GA22-10953SMinistry of Education, Youth and Sports LM2023050Ministry of Health of the Czech Republic NU22-09-00539Ministry of Health of the Czech Republic - conceptual development of research organization (MOÚ,00209805)
6 · The paper itself

Abstract

purposeThe aim of this study was to develop a simple, robust, and easy-to-use calibration procedure for correcting misalignments in rosette MRI k-space sampling, with the objective of producing images with minimal artifacts.

methodsQuick automatic calibration scans were proposed for the beginning of the measurement to collect information on the time course of the rosette acquisition trajectory. A two-parameter model was devised to match the measured time-varying readout gradient delays and approximate the actual rosette sampling trajectory. The proposed calibration approach was implemented, and performance assessment was conducted on both phantoms and human subjects.

resultsThe fidelity of phantom and in vivo images exhibited significant improvement compared with uncorrected rosette data. The two-parameter calibration approach also demonstrated enhanced precision and reliability, as evidenced by quantitative

conclusionAdequate correction of data sampling is a crucial step in rosette MRI. The presented experimental results underscore the robustness, ease of implementation, and suitability for routine experimental use of the proposed two-parameter rosette trajectory calibration approach.

Indexed as

AlgorithmsArtifactsImage Processing, Computer-AssistedMagnetic Resonance ImagingPhantoms, ImagingBrainCalibrationHumansReproducibility of Resultsgradient imperfectionsk‐space misalignmentrosette trajectorytrajectory estimation

Identifiers

PMID39435570
PMCPMC11680729

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.