ArticleIntensive care medicine experimental2024
Clinical implementation of advanced respiratory monitoring with esophageal pressure and electrical impedance tomography: results from an international survey and focus group discussion.
Article in Intensive care medicine experimental, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Challenges and strategies for the identification and correction of patient-ventilator asynchronies in daily practice: a scoping review.Acute and critical care · 2026Article
- New indexes, old habits: a comment on the EIT-derived flow index.Critical care (London, England) · 2026Article
- Setting PEEP in patients with COVID-19-related ARDS: a physiological comparison between methods.Intensive care medicine experimental · 2026Article
- EIT-guided end-expiratory pressure individualization in robotic surgery with high PEEP ventilation: a prospective observational study.BMC anesthesiology · 2026Article
- Recent advances in experimental and clinical applications of chest electrical impedance tomography: a narrative review.Intensive care medicine experimental · 2026Review
- Respiratory therapists' perceptions of electrical impedance tomography in pediatric intensive care: A mixed methods implementation study.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2026Article
- Recommendations for lung ventilation and perfusion assessment with chest electrical impedance tomography in critically ill adult patients: an international evidence-based and expert Delphi consensus study.EClinicalMedicine · 2025Article
- Babies' lungs are not balloons: is it time to embrace electrical impedance tomography?Pediatric research · 2025Article
- Solid-state esophageal pressure sensor for the estimation of pleural pressure: a bench and first-in-human validation study.Critical care (London, England) · 2025Article
- Electrical impedance tomography monitoring in adult ICU patients: state-of-the-art, recommendations for standardized acquisition, processing, and clinical use, and future directions.Critical care (London, England) · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
backgroundPopularity of electrical impedance tomography (EIT) and esophageal pressure (Pes) monitoring in the ICU is increasing, but there is uncertainty regarding their bedside use within a personalized ventilation strategy. We aimed to gather insights about the current experiences and perceived role of these physiological monitoring techniques, and to identify barriers and facilitators/solutions for EIT and Pes implementation.
methodsQualitative study involving (1) a survey targeted at ICU clinicians with interest in advanced respiratory monitoring and (2) an expert focus group discussion. The survey was shared via international networks and personal communication. An in-person discussion session on barriers, facilitators/solutions for EIT implementation was organized with an international panel of EIT experts as part of a multi-day EIT meeting. Pes was not discussed in-person, but we found the focus group results relevant to Pes as well. This was confirmed by the survey results and four additional Pes experts that were consulted.
resultsWe received 138 survey responses, and 26 experts participated in the in-person discussion. Survey participants had diverse background [physicians (54%), respiratory therapists (19%), clinical researchers (15%), and nurses (6%)] with mostly > 10 year ICU experience. 84% of Pes users and 74% of EIT users rated themselves as competent to expert users. Techniques are currently primarily used during controlled ventilation for individualization of PEEP (EIT and Pes), and for monitoring lung mechanics and lung stress (Pes). EIT and Pes are considered relevant techniques to guide ventilation management and is helpful for educating clinicians; however, 57% of EIT users and 37% of Pes users agreed that further validation is needed. Lack of equipment/materials, evidence-based guidelines, clinical protocols, and/or the time-consuming nature of the measurements are main reasons hampering Pes and EIT application. Identified facilitators/solutions to improve implementation include international guidelines and collaborations between clinicians/researcher and manufacturers, structured courses for training and use, easy and user-friendly devices and standardized analysis pipelines.
conclusionsThis study revealed insights on the role and implementation of advanced respiratory monitoring with EIT and Pes. The identified barriers, facilitators and strategies can serve as input for further discussions to promote the development of EIT-guided or Pes-guided personalized ventilation strategies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.