Evidence map›Paper›PMID 39432136›Full record

ArticleIntensive care medicine experimental2024

Clinical implementation of advanced respiratory monitoring with esophageal pressure and electrical impedance tomography: results from an international survey and focus group discussion.

Jantine J Wisse, Gaetano Scaramuzzo, Mariangela Pellegrini, Leo Heunks, Thomas Piraino, Peter Somhorst, Laurent Brochard, Tommaso Mauri, Erwin Ista, Annemijn H Jonkman

Abstract read
In one paragraph

Article in Intensive care medicine experimental, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Respiratory therapists' perceptions of electrical impedance tomography in pediatric intensive care: A mixed methods implementation study.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2026
    Article
  7. Article
  8. Article
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jantine J WisseAdult Intensive Care, Erasmus Medical Center, Dr. Molewaterplein 40, 3015GD, Rotterdam, The Netherlands.
Gaetano ScaramuzzoDepartment of Translation Medicine, University of Ferrara, Ferrara, Italy.
Mariangela PellegriniDepartment of Surgical Sciences, Anaesthesiology and Intensive Care Medicine, Uppsala University, Uppsala, Sweden.
Leo HeunksDepartment of Intensive Care, Radboud University Medical Center, Nijmegen, The Netherlands.
Thomas PirainoDepartment of Anesthesia, McMaster University, Hamilton, ON, Canada.
Peter SomhorstAdult Intensive Care, Erasmus Medical Center, Dr. Molewaterplein 40, 3015GD, Rotterdam, The Netherlands.
Laurent BrochardKeenan Centre for Biomedical Research, Li Ka Shing Knowledge Institute and St. Michael's Hospital, Unity Health Toronto, Toronto, ON, Canada.
Tommaso MauriDepartment of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
Erwin IstaDepartment of Internal Medicine, Division of Nursing Science, Erasmus Medical Center, Rotterdam, The Netherlands.
Annemijn H JonkmanAdult Intensive Care, Erasmus Medical Center, Dr. Molewaterplein 40, 3015GD, Rotterdam, The Netherlands. a.jonkman@erasmusmc.nl.ORCID http://orcid.org/0000-0001-8778-5135

Funding

Netherlands eScience Center NLESC.OEC.2022.002
6 · The paper itself

Abstract

backgroundPopularity of electrical impedance tomography (EIT) and esophageal pressure (Pes) monitoring in the ICU is increasing, but there is uncertainty regarding their bedside use within a personalized ventilation strategy. We aimed to gather insights about the current experiences and perceived role of these physiological monitoring techniques, and to identify barriers and facilitators/solutions for EIT and Pes implementation.

methodsQualitative study involving (1) a survey targeted at ICU clinicians with interest in advanced respiratory monitoring and (2) an expert focus group discussion. The survey was shared via international networks and personal communication. An in-person discussion session on barriers, facilitators/solutions for EIT implementation was organized with an international panel of EIT experts as part of a multi-day EIT meeting. Pes was not discussed in-person, but we found the focus group results relevant to Pes as well. This was confirmed by the survey results and four additional Pes experts that were consulted.

resultsWe received 138 survey responses, and 26 experts participated in the in-person discussion. Survey participants had diverse background [physicians (54%), respiratory therapists (19%), clinical researchers (15%), and nurses (6%)] with mostly > 10 year ICU experience. 84% of Pes users and 74% of EIT users rated themselves as competent to expert users. Techniques are currently primarily used during controlled ventilation for individualization of PEEP (EIT and Pes), and for monitoring lung mechanics and lung stress (Pes). EIT and Pes are considered relevant techniques to guide ventilation management and is helpful for educating clinicians; however, 57% of EIT users and 37% of Pes users agreed that further validation is needed. Lack of equipment/materials, evidence-based guidelines, clinical protocols, and/or the time-consuming nature of the measurements are main reasons hampering Pes and EIT application. Identified facilitators/solutions to improve implementation include international guidelines and collaborations between clinicians/researcher and manufacturers, structured courses for training and use, easy and user-friendly devices and standardized analysis pipelines.

conclusionsThis study revealed insights on the role and implementation of advanced respiratory monitoring with EIT and Pes. The identified barriers, facilitators and strategies can serve as input for further discussions to promote the development of EIT-guided or Pes-guided personalized ventilation strategies.

Indexed as

Advanced respiratory monitoringBarriers and facilitatorsElectrical Impedance Tomography (EIT)Esophageal pressure measurements (Pes)ImplementationPanel discussionSurvey

Identifiers

PMID39432136
PMCPMC11493933

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.