Evidence map›Paper›PMID 39432057›Full record

ArticleAnalytical and bioanalytical chemistry2024

Influence of on-site sampling conditions on the representativeness of the sample for the analysis of trace VOCs in raw renewable gases.

A Legendre, S Bsaibes, C Paijens, J Dugay, Y Courtois, L Cuccia, D Ballestas Castro, D Thiebaut, J Vial

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

A LegendreLSABM, UMR CBI 8231CNRS, ESPCI Paris, PSL Université, 10 rue Vauquelin, Paris, 75005, France. agathe.legendre@espci.fr.ORCID http://orcid.org/0009-0005-0504-6133
S BsaibesRICE (Research and Innovation Center for Energy), GRTgaz, 1-3 rue du Commandant Estienne d'Orves, Villeneuve la Garenne, 92390, France.
C PaijensRICE (Research and Innovation Center for Energy), GRTgaz, 1-3 rue du Commandant Estienne d'Orves, Villeneuve la Garenne, 92390, France.
J DugayLSABM, UMR CBI 8231CNRS, ESPCI Paris, PSL Université, 10 rue Vauquelin, Paris, 75005, France.
Y CourtoisRICE (Research and Innovation Center for Energy), GRTgaz, 1-3 rue du Commandant Estienne d'Orves, Villeneuve la Garenne, 92390, France.
L CucciaRICE (Research and Innovation Center for Energy), GRTgaz, 1-3 rue du Commandant Estienne d'Orves, Villeneuve la Garenne, 92390, France.
D Ballestas CastroRICE (Research and Innovation Center for Energy), GRTgaz, 1-3 rue du Commandant Estienne d'Orves, Villeneuve la Garenne, 92390, France.
D ThiebautLSABM, UMR CBI 8231CNRS, ESPCI Paris, PSL Université, 10 rue Vauquelin, Paris, 75005, France.
J VialLSABM, UMR CBI 8231CNRS, ESPCI Paris, PSL Université, 10 rue Vauquelin, Paris, 75005, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the context of the energy transition and in order to fully manage the integration of renewable and/or low-carbon gases into the gas mix, these new renewable gases need to be characterized, including volatile organic compounds (VOCs) at trace levels that may have an impact on different stages of the gas chain event at low concentrations. This study focuses on sampling because it is the first step in any method for analyzing trace VOCs and its careful execution is essential to ensure reliable results even if the on-site conditions can be variable, such as the external temperature. The stabilization time, the effect of external temperature, and the impact of using an intermediate sample cylinder prior to transfer to tubes were hence studied in the laboratory using a standard gas mixture representative of renewable gases. The latter was also studied using a real sample. To perform this study, VOCs were sampled in Tenax® TA tubes and then analyzed by thermal desorption hyphenated to comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry. The results showed that 45 min were required to stabilize the sampling system and that external temperature had little influence, limited to the heaviest compounds. Finally, the use of a cylinder to temporarily collect gas prior to transfer to tubes led to a loss of compounds, particularly when the cylinder was stored before the transfer.

Indexed as

Gas samplingRenewable gasSample cylinderSorbent tubeVolatile organic compound

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.