Evidence map›Paper›PMID 39430679›Full record

ArticleEuropean heart journal. Case reports2024

Dual-chamber leadless pacemaker in complex adult congenital heart disease: a case report.

Ho Ting Abe Ngan, Davide Fabbricatore, William Regan, Eric Rosenthal, Tom Wong

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Strategies for preventing arrhythmic sudden death in adult congenital heart disease.European heart journal supplements : journal of the European Society of Cardiology · 2026
    Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ho Ting Abe NganDepartment of Cardiac Electrophyioslogy, Royal Brompton and Harefield Hospitals, Guys and St Thomas' NHS Foundation Trust, Sydney Street, London SW3 6NP, UK.ORCID https://orcid.org/0000-0003-0538-961X
Davide FabbricatoreDepartment of Cardiac Electrophyioslogy, Royal Brompton and Harefield Hospitals, Guys and St Thomas' NHS Foundation Trust, Sydney Street, London SW3 6NP, UK.
William ReganDepartment of Cardiac Electrophysiology, Evelina London Children's Hospital, Guys and St Thomas' NHS Foundation Trust, Westminster Bridge Rd, London SE1 7EH, UK.
Eric RosenthalDepartment of Cardiac Electrophysiology, Evelina London Children's Hospital, Guys and St Thomas' NHS Foundation Trust, Westminster Bridge Rd, London SE1 7EH, UK.ORCID https://orcid.org/0000-0003-3030-9749
Tom WongDepartment of Cardiac Electrophyioslogy, Royal Brompton and Harefield Hospitals, Guys and St Thomas' NHS Foundation Trust, Sydney Street, London SW3 6NP, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Atrioventricular block is common with adult congenital heart disease and pacemaker implantation is challenging. Atrioventricular synchronous pacing is important for better haemodynamics. This case reports the implantation of a dual-chamber leadless pacemaker in a patient with univentricular heart physiology and contributes to the literature regarding the management option in complex adult congenital heart disease patients with conduction abnormalities. Case summary: A 25-year-old male with double inlet left ventricular, transposition of great arteries, hypoplastic aortic arch receive multiple surgeries including the Glenn shunt at the age of 1. He presented with 2:1 and 3:1 heart block at the age of 13 with a transvenous dual-chamber pacemaker implanted by pacing the superior vena cava stump and puncturing the Glenn shunt for the ventricular lead. A decade later, lead malfunctioned and the patient progressed to complete heart block. A subcutaneous implantable cardioverter defibrillator was implanted when he was 23 for monomorphic ventricular tachycardia. Given the anticipated challenges with transvenous lead extraction and epicardial pacemaker implantation, we implanted the novel dual-chamber leadless pacemakers which resulted in satisfactory atrioventricular synchronous pacing performance immediately post-op and 2 weeks after the procedure. Discussion: We present a case of a novel dual-chamber leadless pacemaker implantation to maintain atrioventricular synchrony in the patient with complete heart block and univentricular physiology. This case illustrates an additional pacing option in complex adult congenital heart to maintain atrioventricular synchrony.

Indexed as

ACHDAtrioventricular synchronyCase reportDual-chamber pacingLeadless pacemakerUniventricular heart

Identifiers

PMID39430679
PMCPMC11489873

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.