Evidence map›Paper›PMID 39430648›Full record

ArticleJournal of clinical orthopaedics and trauma2024

Ceramic-on-ceramic

José Cordero-Ampuero, Paula Velasco, Jorge Payo-Rodríguez, Pablo Peñalver-Andrada, Enrique González-Fernández

Erratum issuedAbstract read
In one paragraph

Article in Journal of clinical orthopaedics and trauma, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Ceramic-on-ceramic versus polyethylene-based bearings in total hip arthroplasty: a meta-analysis.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
    Pooled it
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

José Cordero-AmpueroDepartment of Orthopaedic Surgery, University Hospital La Princesa, c/ Diego de León 62, 28006, Madrid, Spain.
Paula VelascoDepartment of Orthopaedic Surgery, University Hospital La Princesa, c/ Diego de León 62, 28006, Madrid, Spain.
Jorge Payo-RodríguezDepartment of Orthopaedic Surgery, University Hospital La Princesa, c/ Diego de León 62, 28006, Madrid, Spain.
Pablo Peñalver-AndradaDepartment of Orthopaedic Surgery, University Hospital La Princesa, c/ Diego de León 62, 28006, Madrid, Spain.
Enrique González-FernándezDepartment of Orthopaedic Surgery, University Hospital La Princesa, c/ Diego de León 62, 28006, Madrid, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Few studies compare complications and results in ceramic-ceramic (CeCe) Methods: Bearing surface: CeCe (Biolox Forte/Delta) in 35 cases of 53.7 ± 10.6 years (25-69) (21 males, 60 %), Me-XLPE in 65 of 69.0 ± 8.9 years (42-81) (36 males, 55 %); age was different (p < 0.00001), but not sex (p = 0.6565). Head diameter: 28 mm in 19, 32 mm in 9 and 36 mm in 7 CeCe hips; 28 mm in 63, 32 mm in 1 and 36 mm in 1 Me-XLPe hips. Follow-up: 10.5 ± 3.1 years (1-15) in ceramic, 9.8 ± 3.8 years (2-15) in Me-XLPE. Results: Survivorship without additional surgery or closed reduction at 15 years: 91.0 % in ceramic, 83.8 % in Me-XLPE joints. Survivorship without component exchange at 15 years: 93.9 % in ceramic, 93.6 % in Me-XLPE joints. Complications: CeCe joints suffered 2 infections, 1 isolated dislocation, and 1 Vancouver-C fracture. Me-XLPE joints presented 2 infections (p = 0.6101), 5 isolated (p = 0.6621) and 2 recurrent dislocations (p = 0.5454), and 4 Vancouver-B fractures (p = 0.6548).At final follow-up, Harris Hip Score averaged 93.2 ± 13.7 (23-100) in ceramic and 94.3 ± 8.7 (65-100) in XLPE joints (p = 0.64552).Measured radiographic wear reached 0.06 ± 0.38 mm (0-1.5) (0.0057 mm/year) in CeCe and 0.16 ± 0.5 mm (0-2) (0.0163 mm/year) in Me-XLPE (p = 0.30302). At final radiographic follow-up, osteolysis was present in 8 Charnley-De Lee zones (6 patients) (17 %) of ceramic cups and in 25 zones (15 patients) (23 %) of XLPE cups (p = 0.980127). Conclusion: At 10 years follow-up, metal-XLPE and ceramic-ceramic joints in Furlong-H-A.C. Active present no significant differences in complications, clinical score, wear, acetabular osteolysis, or survivorship without component exchange.Nevertheless, survivorship without any surgery or closed reduction is different because of the high rate of dislocation in 28 mm metal-poly joints.

Indexed as

Ceramic jointCross-link polyethyleneHip arthroplastySurvivorshipWear

Identifiers

PMID39430648
PMCPMC11483472

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.