Evidence map›Paper›PMID 39429615›Full record

ArticleQuantitative imaging in medicine and surgery2024

Monoenergetic reconstructions and iodine density maps for visualization of coronary artery stents using 8-cm dual-layer detector spectral computed tomography: an

Lihong Chen, Ning Pan, Bin Hu, Yaofeng Li, Shushan Dong, Yinan Zhou, Jianxin Guo, Jian Yang, Yongbai Luo, Zhijie Jian

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Lihong Chen *Department of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
Ning Pan *Bayer Healthcare Company Limited, Xi'an, China.
Bin HuDepartment of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
Yaofeng LiDepartment of Radiology, the East District of The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
Shushan DongPhilips HealthCare, Clinical Science, Beijing, China.
Yinan ZhouPhilips HealthCare, Clinical Science, Beijing, China.
Jianxin GuoDepartment of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
Jian YangDepartment of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
Yongbai LuoDepartment of Cardiovascular Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
Zhijie JianDepartment of Radiology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The effectiveness of coronary computed tomography (CT) angiography in assessing stent restenosis is hindered by heavy metal artifacts. This study aimed to evaluate the image quality of monoenergetic reconstructions and iodine density map for coronary stent imaging using an 8-cm dual-layer detector spectral CT. Methods: In this study, 8 stents with a diameter <3 mm (group A) and 10 with a diameter ≥3 mm (group B) were placed in plastic tubes filled with iodinated contrast media and scanned. The internal diameter of the prepared stents was then measured by intravascular ultrasound. The reconstructed images included iodine density maps, conventional images, and different energy levels. The visualization of the stent lumen and stent structure was subjectively assessed using a 4-point Likert scale. The objective evaluation was performed using the in-stent lumen signal-to-noise ratio (SNRis), non-stent lumen SNR (SNRns), internal diameter difference (IDD), and blooming artifact index (BAI). The Friedman test and analysis of variance were used for multiple comparisons. Results: For lumen visualization, the optimal monoenergetic images received the highest score for both group A (2.56±0.51) and group B (3.1±0.55). Multiple comparisons showed that there were significant differences between the optimal monoenergetic images and iodine density maps. However, for stent structure, iodine density maps received the highest score for group A (3.0±0.52) and group B (3.8±0.41). For quantitative assessment, the optimal monoenergetic images had the highest SNRis and SNRns, while the iodine density maps had the lowest SNRis and SNRns. For IDD and BAI, the iodine density maps yielded the smallest value. Conclusions: The monoenergetic images on the second-generation dual-layer detector CT provide better visualization of the lumen and higher SNR. However, iodine density maps are superior for evaluating stent structure and IDD and BAI compared to monoenergetic and conventional reconstructions.

Indexed as

Computed tomography (CT)coronary artery diseasedual-layer detectorin-stent restenosisstent