Evidence map›Paper›PMID 39429579›Full record

ArticleQuantitative imaging in medicine and surgery2024

Comparison of single shot and multishot diffusion-weighted imaging in 5-T magnetic resonance imaging for brain disease diagnosis.

Hao Chen, Runyu Tang, Xiaopeng Song, Ran Zong, Jie Liu, Chuyue Jin, Kexue Deng

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hao ChenDepartment of Radiology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China.ORCID https://orcid.org/0000-0002-6650-8240
Runyu TangCentral Research Institute, United Imaging Healthcare, Shanghai, China.
Xiaopeng SongCentral Research Institute, United Imaging Healthcare, Shanghai, China.
Ran ZongDepartment of Radiology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China.
Jie LiuDepartment of Radiology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China.
Chuyue JinDepartment of Radiology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China.
Kexue DengDepartment of Radiology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Diffusion-weighted imaging (DWI) with single-shot echo-planar imaging (ssEPI) is a valuable tool for detecting acute brain lesions but does suffer from image distortions. Multishot echo-planar imaging (msEPI) is a technique for reducing such distortions. This study aimed to compare the image quality and diagnostic efficacy of ssEPI- and msEPI-DWI at 5.0 T for brain disease detection. Methods: This study retrospectively reviewed images of 107 consecutive patients with suspected brain diseases who underwent ssEPI- and msEPI-DWI at 5.0 T at the First Affiliated Hospital of University of Science and Technology of China from August 2023 to September 2023. Two radiologists independently graded image quality and measured the image distortion. Signal-to-noise ratio, contrast-to-noise ratio, and apparent diffusion coefficient (ADC) were calculated and compared between ssEPI- and msEPI-DWI. Image quality scores were compared using the Wilcoxon test and other continuous variables by the paired Results: Image quality evaluation and distortion analysis revealed that msEPI-DWI significantly outperformed ssEPI-DWI (two-sided P<0.001). No significant difference was observed in signal-to-noise ratio, contrast-to-noise ratio, or ADC values between msEPI- and ssEPI-DWI (two-sided P≥0.601). The ADC values of msEPI- and ssEPI-DWI showed strong correlations for both lesions (r=0.97) and contralateral normal tissues (r=0.91) (two-sided P<0.001). Compared to those of the contralateral white matter, ADC values of low-grade gliomas (LGGs) were significantly higher [ssEPI-DWI: 1,119.9±273.1 Conclusions: As compared to ssEPI-DWI, msEPI-DWI, when performed at 5.0 T, demonstrated superior image quality and less anatomical distortion in a wide spectrum of brain diseases and showed promising diagnostic performance for LGGs and ACI. In the future, msEPI-DWI at 5.0 T could become clinically routine in the diagnosis and grading of brain disorders.

Indexed as

apparent diffusion coefficient (ADC)Diffusion-weighted imaging (DWI)multishot echo-planar imaging (msEPI)

Identifiers

PMID39429579
PMCPMC11485352

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.