Evidence map›Paper›PMID 39427085›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Leg length discrepancy risk differs between fit-and-fill and taper wedge stems across Dorr types.

Yueh-Ting Hung, Cheng-Yang Chang, Kun-Han Lee, Wei-Lin Chang, Shang-Wen Tsai, Cheng-Fong Chen, Po-Kuei Wu, Wei-Ming Chen

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yueh-Ting HungDepartment of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan.
Cheng-Yang ChangDepartment of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan.
Kun-Han LeeDepartment of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan.
Wei-Lin ChangDepartment of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan.
Shang-Wen TsaiDepartment of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan. swtsai.vghtpe@gmail.com.ORCID http://orcid.org/0000-0002-2523-5012
Cheng-Fong ChenDepartment of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan.
Po-Kuei WuDepartment of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan.
Wei-Ming ChenDepartment of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe comparison between the cementless taper wedge stem and fit-and-fill stem in total hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly assessed. This study aimed to compare the risk of leg length discrepancy (LLD) ≥ 10 mm between these two stem types in Dorr type A, B, and C femurs. MATERIALS AND

methodsFrom April 2015 through April 2021, we analyzed 1178 unilateral primary cementless THA procedures. We categorized all procedures into three groups: Dorr type A (N = 220, 18.7%), B (N = 875, 74.3%), and C (N = 83, 7.0%). Within each Dorr type, we compared the incidence and risk of postoperative LLD ≥ 10 mm between the two stem types. The factors considered in the multivariate regression analyses included stem type, age, sex, body mass index, diagnosis, canal flare index, femoral cortical index and stem alignment.

resultsThe taper wedge stem group had a higher overall incidence of LLD ≥ 10 mm (12.8% vs. 7.4%, P = 0.012) and in Dorr type A femurs (22.2% vs. 7.6%, P = 0.014), compared with the fit-and-fill stem group. In multivariate analysis, the taper wedge stem exhibited an increased risk of LLD ≥ 10 mm only in Dorr type A femurs (aOR: 3.449, 95% CI: 1.325-8.794). The incidence and risk of LLD ≥ 10 mm were not different between the two stems in Dorr type B and C femurs.

conclusionsThe taper wedge stem demonstrated an elevated risk of LLD ≥ 10 mm in Dorr type A femurs compared with the fit-and-fill stem, necessitating meticulous preoperative templating and intraoperative femoral canal preparation.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisLeg Length InequalityProsthesis DesignAdultAgedFemaleFemurHumansIncidenceMaleMiddle AgedPostoperative ComplicationsRetrospective StudiesRisk FactorsCementless stemComplicationDorr classificationLeg length discrepancyProximal femoral morphologyTotal hip arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.