Impact of an institutional process change adopting end-systolic coronary CTA acquisition and automated dose selection on patient throughput and image quality.
Article in Journal of cardiovascular computed tomography. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
introductionGuidelines recommend prospective ECG-triggered mid-diastolic coronary computed tomographic angiography (CCTA) acquisition after achieving optimal heart rate (HR) control in order to optimize scan image quality. With dual-source CCTA, prospective end-systolic acquisition has been shown to be less prone to motion artifacts at higher heart rates and may improve scan and CT laboratory efficiency by allowing CCTA without routine pre-scan beta-blocker (BB) administration.
methodsWe implemented an institutional process change in CCTA performance effective January 2023, comprising a transition from prospective ECG-triggered mid-diastolic acquisitions individually supervised by a physician at the scanner to an algorithmic approach predominately utilizing prospective end-systolic acquisition (200-400 ms after R peak), employing an automated dose selection algorithm, without BB administration. All scans were performed on a third-generation 192-slice dual-source scanner. We reviewed 300 consecutive CCTAs done pre- and post-process change in Jan 2022 (phase 0), Jan 2023 (phase 1), and in May 2023 (phase 2) after implementation of a process improvement involving more selective utilization of automated tube potential/current algorithms (CARE kV) to optimize image quality. Coronary segmental image quality was assessed by two experienced CCTA readers by consensus using an 18-segment SCCT model on a 5-point Likert scale (1 = non-interpretable; 2 = poor; 3 = acceptable; 4 = good; 5 = excellent). Measures of radiation dose, medication administration, and time required for patient scanning were compared. Logistic regression was used to determine factors associated with patient-level reduction in image quality (IQ) and with repeat scans.
resultsPost-process change, there was a significant reduction in the median overall patient appointment [phase 0: 95 (75-125) min vs. phase 1: 68 (52-88) min and phase 2: 72 (59-90) min; P < 0.001] and scan times [phase 0: 13 (10-16) min vs. phase 1: 8 (6-13) min and phase 2: 9 (7-13) min; P < 0.001]. Median IQ score in both post-process change phases was 4 (4-5) compared to a median score of 5 (4-5) pre-process change (P for comparison <0.001). The majority of segments post-process change had "good" IQ (Phase 1 segmental IQ scores: 5 = 36.7 %, 4 = 46.8 %, 3 = 13 %, 2 = 2.6 %, 1 = 0.9 %; Phase 2 segmental IQ scores: 5 = 26 %, 4 = 49.7 %, 3 = 16.3 %, 2 = 6.1 %, 1 = 1.9 %), whereas pre-process change, the majority of segments had "excellent" IQ (Phase 0 segmental IQ scores: 5 = 56 %, 4 = 34.3 %, 3 = 7.5 %, 2 = 1.8 %, 1 = 0.4 %) There was no significant increase in non-interpretable scans at the patient level. The 22 % re-scan rate in phase 1 (vs. 6 % in phase 0, P = .002) improved to 15 % in phase 2. While patient related factors of body mass index [adjusted OR obese 2.64, 95 % CI 1.12-6.51, P = 0.03; aOR morbidly obese 6.94, 95 % CI 2.21-23.52, P = 0.001] and average HR [aOR (per 10 bpm increase) 1.51, 95 % CI 1.21-1.9, P < 0.001] were associated with the scoring of any segment as ≤ 3 at the patient level in a fully adjusted model, the improved phase 2 of the process change was not [aOR 1.61, 95 % CI 0.78-3.32].
conclusionImplementation of an institutional process change utilizing prospective ECG-triggered dual-source end-systolic acquisition avoided the use of beta-blockers, significantly reduced patient appointment and scan times with acceptable diagnostic performance.