ArticleScientific reports2024
A hybrid deep learning network for automatic diagnosis of cardiac arrhythmia based on 12-lead ECG.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Intelligent Real-Time Healthcare and Biomedical Monitoring Systems: A Narrative Review of AI, IoT, and Emerging Technologies.Bioengineering (Basel, Switzerland) · 2026Review
- From Chaos to Care: Personalized AI for Early Cardiac Arrhythmia Warning.Machine learning with applications · 2026Article
- AI-Assisted Multilabel Diagnosis of 12-Lead Electrocardiograms Using an Interpretable Stacked Deep Learning Model with External Validation.Diagnostics (Basel, Switzerland) · 2026Article
- CaReS-BiNet: A multi-scale deep learning framework for ECG arrhythmia classification.Scientific reports · 2026Article
- Wheeze detection in real-world pediatric care: AI applied to smartphone lung auscultation.European journal of pediatrics · 2026Observational
- Explainable hybrid deep learning framework with Grad-CAM for heartbeat-level arrhythmia classification.Frontiers in physiology · 2026Article
- An explainable deep learning framework for trustworthy arrhythmia detection from ECG signals.Scientific reports · 2025Article
- MS-LTCAF: A Multi-Scale Lead-Temporal Co-Attention Framework for ECG Arrhythmia Detection.Bioengineering (Basel, Switzerland) · 2025Article
- Interpretable Deep Learning Models for Arrhythmia Classification Based on ECG Signals Using PTB-X Dataset.Diagnostics (Basel, Switzerland) · 2025Article
- MAK-Net: A Multi-Scale Attentive Kolmogorov-Arnold Network with BiGRU for Imbalanced ECG Arrhythmia Classification.Sensors (Basel, Switzerland) · 2025Article
- A lightweight 1D convolutional neural network model for arrhythmia diagnosis from electrocardiogram signal.Physical and engineering sciences in medicine · 2025Article
- Advances in Electrocardiogram-Based Artificial Intelligence Reveal Multisystem Biomarkers.Journal of clinical & experimental cardiology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Cardiac arrhythmias are the leading cause of death and pose a huge health and economic burden globally. Electrocardiography (ECG) is an effective technique for the diagnosis of cardiovascular diseases because of its noninvasive and cost-effective advantages. However, traditional ECG analysis relies heavily on the clinical experience of physicians, which can be challenging and time-consuming to produce valid diagnostic results. This work proposes a new hybrid deep learning model that combines convolutional neural network (CNN) and bidirectional gated recurrent unit (BiGRU) with multi-head attention (CBGM model). Specifically, the model consists of seven convolutional layers with varying filter sizes (4, 16, 32, and 64) and three pooling layers, respectively, while the BiGRU module includes two layers with 64 units each followed by multi-head attention (8-heads). The combination of CNN and BiGRU effectively captures spatio-temporal features of ECG signals, with multi-head attention comprehensively extracted global correlations among multiple segments of ECG signals. The validation in the MIT-BIH arrhythmia database achieved an accuracy of 99.41%, a precision of 99.15%, a specificity of 99.68%, and an F1-Score of 99.21%, indicating its robust performance across different evaluation metrics. Additionally, the model's performance was evaluated on the PTB Diagnostic ECG Database, where it achieved an accuracy of 98.82%, demonstrating its generalization capability. Comparative analysis against previous methods revealed that our proposed CBGM model exhibits more higher performance in automatic classification of arrhythmia and can be helpful for assisting clinicians by enabling real-time detection of cardiac arrhythmias during routine ECG screenings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.