ArticleBiomedical optics express2024
Portable, smartphone-linked, and miniaturized photonic resonator absorption microscope (PRAM Mini) for point-of-care diagnostics.
Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Ultrasensitive non-enzymatic protein detection using proximity immunoassay with photonic resonator absorption microscopy.Npj biosensing · 2026Article
- Photonic resonator absorption microscopy: why consider metallic and magneto-plasmonic nano-assemblies over bare nanoparticles for digital biosensing?Analytical and bioanalytical chemistry · 2025Article
- Oligonucleotide surface attachment by tosylation for digital detection of microRNA using photonic resonator absorption microscopy.APL bioengineering · 2025Article
- Physically grounded deep learning-enabled gold nanoparticle localization and quantification in photonic resonator absorption microscopy for digital resolution molecular diagnostics.Biosensors & bioelectronics · 2025Article
- Digital Immunoassay for Rapid Detection of SARS-CoV-2 exposure in a Broad Spectrum of Animals.IEEE sensors journal · 2025Article
- Photonic Crystal Enhanced Microscopy on a 2D Photonic Crystal Surface.Advanced materials technologies · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
We report the design, development, and characterization of a miniaturized version of the photonic resonator absorption microscope (PRAM Mini), whose cost, size, and functionality are compatible with point-of-care (POC) diagnostic assay applications. Compared to previously reported versions of the PRAM instrument, the PRAM Mini components are integrated within an optical framework comprised of an acrylic breadboard and plastic alignment fixtures. The instrument incorporates a Raspberry Pi microprocessor and Bluetooth communication circuit board for wireless control and data connection to a linked smartphone. PRAM takes advantage of enhanced optical absorption of ∼80 nm diameter gold nanoparticles (AuNP) whose localized surface plasmon resonance overlaps with the ∼625 nm resonant reflection wavelength of a photonic crystal (PC) surface. When illuminated with wide-field low-intensity collimated light from a ∼617 nm wavelength red LED, each AuNP linked to the PC surface results in locally reduced reflection intensity, which is visualized by observing dark spots in the PC-reflected image with an inexpensive CMOS image sensor. Each AuNP in the image field of view can be easily counted with digital resolution. We report upon the selection of optical/electronic components, image processing algorithm, and contrast achieved for single AuNP detection. The instrument is operated via a wireless connection to a linked mobile device using a custom-developed software application that runs on an Android smartphone. As a representative POC application, we used the PRAM Mini as the detection instrument for an assay that measures the presence of antibodies against SARS-CoV-2 infection in cat serum samples, where each dark spot in the image represents a complex between one immobilized viral antigen, one antibody molecule, and one AuNP tag. With dimensions of 23 × 21 × 10 cm
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.