ArticlePediatric research2026
Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth.
Article in Pediatric research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Non-Contact and Wireless Wearable Technologies for Neonatal Vital Sign Monitoring in the Delivery Room-A Scoping Review.Children (Basel, Switzerland) · 2026Review
- Challenges and opportunities in neonatal monitoring: insights on forehead photoplethysmography sensors.Pediatric research · 2026Article
- Soft, all-in-one, nanomembrane wearable system for advancing neonatal health monitoring in Ethiopia.NPJ digital medicine · 2025Article
- A Framework to Evaluate Feasibility, Safety, and Accuracy of Wireless Sensors in the Neonatal Intensive Care Unit: Oxygen Saturation Monitoring.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
backgroundTo study the feasibility of measuring heart rate (HR) and oxygen saturation (SpO
methodsVital signs were measured and compared between forehead-mounted reflectance (remittance) photoplethysmography sensor (fhPPG) and a wrist-mounted pulse oximeter sensor (wrPO), from 20 enrolled term newborns born via elective caesarean section, during the first 10 min of life.
resultsFrom the datasets available (n = 13), the median (IQR) sensor placement times for fhPPG, ECG and wrPO were 129 (70) s, 143 (68) s, and 159 (76) s, respectively, with data recorded for up to 10 min after birth. The success rate (percentage of total possible HR values reported once sited) of fhPPG (median = 100%) was higher compared to wrPO (median = 69%) during the first 6 min of life (P < 0.005). Both devices exhibited good HR agreement with ECG, achieving >95% agreement by 3 (fhPPG) and 4 (wrPO) min. SpO
conclusionIn the period of newborn transition at birth in healthy term infants, forehead measurement of vital signs was feasible and exhibited greater HR accuracy and higher estimated SpO IMPACT: This study demonstrates the feasibility of continuously monitoring heart rate and oxygen saturation from an infant's forehead in the delivery room immediately after birth. Significantly higher SpO
Indexed as
Identifiers
What OpenQuestion holds
Registered trials