Ensuring Clinical Excellence: The Mindray SAL9000 Biochemical Immunoassay System.

Zhenzhen Zou, Honghui Tang, Erya Xiao, Yu Zhou, Xuebei Yin, Zhen Hu, Yang Cai, Qingzhen Han, Lin Wang

Abstract read
PubMed Publisher
In one paragraph

Article in Cell biochemistry and biophysics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Zhenzhen ZouCenter of Clinical Laboratory, The Fourth Affiliated of Soochow University, Suzhou, Jiangsu, 215000, China.
Honghui TangCenter of Clinical Laboratory, The Fourth Affiliated of Soochow University, Suzhou, Jiangsu, 215000, China.
Erya XiaoCenter of Clinical Laboratory, The Fourth Affiliated of Soochow University, Suzhou, Jiangsu, 215000, China.
Yu ZhouSuzhou Affiliated Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Suzhou, Jiangsu, 215000, China.
Xuebei YinCenter of Clinical Laboratory, The Fourth Affiliated of Soochow University, Suzhou, Jiangsu, 215000, China.
Zhen HuCenter of Clinical Laboratory, The Fourth Affiliated of Soochow University, Suzhou, Jiangsu, 215000, China.
Yang CaiCenter of Clinical Laboratory, The Fourth Affiliated of Soochow University, Suzhou, Jiangsu, 215000, China.
Qingzhen HanCenter of Clinical Laboratory, The Fourth Affiliated of Soochow University, Suzhou, Jiangsu, 215000, China.
Lin WangCenter of Clinical Laboratory, The Fourth Affiliated of Soochow University, Suzhou, Jiangsu, 215000, China. 13962504512@163.com.

Funding

Department of Science and Technology of Suzhou, Jiangsu Province SZM2022022
6 · The paper itself

Abstract

This study aimed to evaluate the performance and clinical laboratory adaptability of the Mindray SAL9000 biochemical immunoassay automation system, ensuring compliance with ISO 15189 standards and relevant national requirements. We conducted comprehensive performance verification tests on 21 biochemical analytes and 15 immunoassays, including precision, accuracy, linear bias, measurement range assessments, interference testing, reference range validation, inter-instrument comparison, and carryover verification. The Mindray SAL9000 demonstrated high performance across various parameters, with all analytes showing good linearity and minimal bias. While specific interfering substances affected some analytes, the system showed excellent resistance to common interferences such as hemolysis, ascorbic acid, and jaundice. The inter-instrument comparison with the BS2000M and Roche 702 indicated a good correlation, with most parameters showing biases of less than 10%, although exceptions were noted for ALT and AST. In conclusion, the Mindray SAL9000 meets clinical requirements through its high precision, excellent accuracy, and broad measurement range, making it a reliable and adaptable choice for clinical outpatient and emergency laboratories.

Indexed as

ImmunoassayHumansReproducibility of ResultsAccuracy validationBiochemical immunoassayInstrument comparisonInterference testingMindray SAL9000Precision verification