Evidence map›Paper›PMID 39416686›Full record

ArticleACS ES&T engineering2024

Porous Iron Electrodes Reduce Energy Consumption During Electrocoagulation of a Virus Surrogate: Insights into Performance Enhancements Using Three-Dimensional Neutron Computed Tomography.

Kyungho Kim, Cesar Castillo, Gyoung G Jang, Yuxuan Zhang, Costas Tsouris, Shankararaman Chellam

Abstract read
In one paragraph

Article in ACS ES&T engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Engineering Microbial-Electrochemical Interfaces for Sustainable Water Purification.Water environment research : a research publication of the Water Environment Federation · 2026
    Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kyungho KimDepartment of Civil & Environmental Engineering, Texas A&M University, College Station, Texas 77843, United States.ORCID https://orcid.org/0000-0001-9152-3189
Cesar CastilloManufacturing Science Division, Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee 37831, United States.ORCID https://orcid.org/0009-0000-2481-121X
Gyoung G JangManufacturing Science Division, Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee 37831, United States.ORCID https://orcid.org/0000-0003-4305-8723
Yuxuan ZhangNeutron Scattering Division, ORNL, Oak Ridge, Tennessee 37831, United States.ORCID https://orcid.org/0000-0002-0083-1408
Costas TsourisManufacturing Science Division, Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee 37831, United States.ORCID https://orcid.org/0000-0002-0522-1027
Shankararaman ChellamDepartment of Civil & Environmental Engineering, Texas A&M University, College Station, Texas 77843, United States.ORCID https://orcid.org/0000-0001-9173-1439

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrocoagulation has attracted significant attention as an alternative to conventional chemical coagulation because it is capable of removing a wide range of contaminants and has several potential advantages. In contrast to most electrocoagulation research that has been performed with nonporous electrodes, in this study, we demonstrate energy-efficient iron electrocoagulation using porous electrodes. In batch operation, investigation of the external pore structures through optical microscopy suggested that a low porosity electrode with sparse connection between pores may lead to mechanical failure of the pore network during electrolysis, whereas a high porosity electrode is vulnerable to pore clogging. Electrodes with intermediate porosity, instead, only suffered a moderate surface deposition, leading to electrical energy savings of 21% and 36% in terms of electrocoagulant delivery and unit log virus reduction, respectively. Neutron computed tomography revealed the critical role of electrode porosity in utilizing the electrode's internal surface for electrodissolution and effective delivery of electrocoagulant to the bulk. Energy savings of up to 88% in short-term operation were obtained with porous electrodes in a continuous flow-through system. Further investigation on the impact of current density and porosity in long-term operation is desired as well as the capital cost of porous electrodes.

Identifiers

PMID39416686
PMCPMC11474953

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.