ArticleJournal of medical imaging (Bellingham, Wash.)2024
Deep learning architecture for scatter estimation in cone-beam computed tomography head imaging with varying field-of-measurement settings.
Article in Journal of medical imaging (Bellingham, Wash.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Review of GPU-based Monte Carlo simulation platforms for transmission and emission tomography in medicine.Physics in medicine and biology · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: X-ray scatter causes considerable degradation in the cone-beam computed tomography (CBCT) image quality. To estimate the scatter, deep learning-based methods have been demonstrated to be effective. Modern CBCT systems can scan a wide range of field-of-measurement (FOM) sizes. Variations in the size of FOM can cause a major shift in the scatter-to-primary ratio in CBCT. However, the scatter estimation performance of deep learning networks has not been extensively evaluated under varying FOMs. Therefore, we train the state-of-the-art scatter estimation neural networks for varying FOMs and develop a method to utilize FOM size information to improve performance. Approach: We used FOM size information as additional features by converting it into two channels and then concatenating it to the encoder of the networks. We compared our approach for a U-Net, Spline-Net, and DSE-Net, by training them with and without the FOM information. We utilized a Monte Carlo-simulated dataset to train the networks on 18 FOM sizes and test on 30 unseen FOM sizes. In addition, we evaluated the models on the water phantoms and real clinical CBCT scans. Results: The simulation study demonstrates that our method reduced average mean-absolute-percentage-error for U-Net by 38%, Spline-Net by 40%, and DSE-net by 33% for the scatter estimation in the 2D projection domain. Furthermore, the root-mean-square error on the 3D reconstructed volumes was improved for U-Net by 43%, Spline-Net by 30%, and DSE-Net by 23%. Furthermore, our method improved contrast and image quality on real datasets such as water phantom and clinical data. Conclusion: Providing additional information about FOM size improves the robustness of the neural networks for scatter estimation. Our approach is not limited to utilizing only FOM size information; more variables such as tube voltage, scanning geometry, and patient size can be added to improve the robustness of a single network.