Evidence map›Paper›PMID 39414755›Full record

ArticleJournal of ultrasound2025

Comparing the efficacy of multiple quantitative and qualitative ultrasound parameters for the diagnosis of carpal tunnel syndrome.

Isha Gupta, Shashank Sharma, Kshitij Gupta, Meenu Bagarhatta, Naima Mannan, Parul Gupta, Vikas Jhanwar, Deepak Gupta, Jitendra Yadav

Abstract readComparative Study
In one paragraph

Article in Journal of ultrasound, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Carpal Tunnel Syndrome Diagnosis: A Narrative Review of Complementary Roles of Neuromuscular Ultrasound and Electrodiagnostic Studies.Medical science monitor : international medical journal of experimental and clinical research · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Isha GuptaDepartment of Radio-Diagnosis, SMS Medical College and Attached Group of Hospitals, Jaipur, India. ishagupta2707@gmail.com.ORCID http://orcid.org/0000-0002-0619-9124
Shashank SharmaDepartment of Radio-Diagnosis, SMS Medical College and Attached Group of Hospitals, Jaipur, India.
Kshitij GuptaRajasthan University of Health Sciences, Jaipur, India.
Meenu BagarhattaDepartment of Interventional Radiology, SMS Medical College and Attached Group of Hospitals, Jaipur, India.
Naima MannanDepartment of Radio-Diagnosis, SMS Medical College and Attached Group of Hospitals, Jaipur, India.
Parul GuptaDepartment of Radio-Diagnosis, SMS Medical College and Attached Group of Hospitals, Jaipur, India.
Vikas JhanwarDepartment of Radio-Diagnosis, SMS Medical College and Attached Group of Hospitals, Jaipur, India.
Deepak GuptaDepartment of Statistics, Rajasthan University, Jaipur, India.
Jitendra YadavSMS Medical College and Attached Group of Hospitals, Jaipur, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCarpal tunnel syndrome (CTS) is a compression neuropathy causing significant morbidity. Over the years, ultrasound has been evaluated as an alternative to nerve conduction study (NCS) for diagnosing CTS, however, there is no consensus as to which ultrasound parameter is the best. Our study aimed to determine and compare the efficacy of various ultrasound-based variables for diagnosis of CTS.

methods80 patients with clinical suspicion of CTS underwent ultrasound examination with calculation of cross-sectional area (CSA), delta CSA, wrist forearm ratio (WFR), palmer bowing (PB), flattening ratio (FR), flexor retinaculum thickness (FT), and evaluation of echogenicity and vascularity of median nerve. NCS was taken as the gold standard and the diagnostic efficacy of all these variables was compared, followed by receiver operator curve (ROC) analysis.

resultsDelta CSA had the highest accuracy (91.25%), followed by CSAc (80%), WFR (78.75%), and PB (73.75%). Youden's index and sensitivity were highest for delta CSA (0.783 and 96.15% respectively), while specificity was highest for FT (89.29%). The highest area under the curve was noted for delta CSA (97.1%), followed by WFR (AUC = 87.4%) and CSAc (AUC = 86.0%).

conclusionDelta CSA was found to be the best ultrasound parameter for diagnosis of CTS, followed by CSAc, WFR, and PB, and can be used as an alternative to NCS. Using ROC analysis this study also predicted the best cut-off values for these parameters which could improve their diagnostic accuracy and further research is needed to confirm these findings.

Indexed as

Carpal Tunnel SyndromeAdultAgedFemaleHumansMaleMedian NerveMiddle AgedSensitivity and SpecificityUltrasonographyCarpal tunnel syndromeCross sectional areaFlexor retinaculumMedian nerveUltrasound

Identifiers

PMID39414755
PMCPMC11947341

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.