Evidence map›Paper›PMID 39413544›Full record

ArticleJournal of the mechanical behavior of biomedical materials2024

Elastic properties of 3D printed clavicles are closer to cadaveric bones of elderly donors than commercial synthetic bones.

Kathryn S Strand, Elizabeth Silvestro, Iman Naqvi, Michael W Hast

Abstract read
In one paragraph

Article in Journal of the mechanical behavior of biomedical materials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Kathryn S StrandDepartment of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA. Electronic address: strandk@seas.upenn.edu.
Elizabeth SilvestroDepartment of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA. Electronic address: silvestro@chop.edu.
Iman NaqviDepartment of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA. Electronic address: naqvii1@tcnj.edu.
Michael W HastDepartment of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA; Department of Mechanical Engineering, University of Delaware, Newark, DE, USA. Electronic address: hast@udel.edu.

Funding

Overall: Resource-based Center for Musculoskeletal Disorders Research (Overall Application)P30AR069619 · NIAMS · UNIVERSITY OF PENNSYLVANIA · PI LOUIS J SOSLOWSKY · 2016 to 2026
$9.1M
NIAMS NIH HHS P30 AR069619
6 · The paper itself

Abstract

Synthetic bone models have increasing utility in orthopaedic research due to their low cost and low variability and have been shown to be biomechanically equivalent to human bones in a variety of ways. The rise in additive manufacturing (AM) for orthopaedic applications presents an opportunity to construct synthetic whole-bone models for biomechanical testing applications, but there is a lack of research comparing these AM models to cadaveric or commercially available bone surrogates. This study compares the mechanical properties of 3D printed clavicle models to commercially available (4th generation Sawbones) and human cadaveric clavicles via nondestructive cyclic 4-point bending, axial compression, and torsion, and a final axial compression test to failure. Commercially available synthetic clavicles had 57.8-203% higher superior-inferior bending rigidity (p < 0.0001), 80.9-198% higher axial stiffness (p < 0.001), and 314-557% higher torsional rigidity (p < 0.05) on average than AM and cadaveric clavicles. Cadaveric and AM clavicles printed from a BoneMatrix/VeroWhite composite material had similar failure mechanisms under axial compression while AM VeroWhite clavicles experienced catastrophic failure, but these groups did not have significantly different ultimate failure loads. Together, these results demonstrate that current commercially available synthetic clavicles may be too rigid to emulate the mechanical properties of elderly cadaveric clavicles, and that AM bone models can closely mimic these cadaveric bones in a variety of biomechanical loading schemes. These results show promising applications for future work using 3D printed bone surrogates for biomechanical analysis of orthopaedic implants and other surgical repair techniques.

Indexed as

CadaverClavicleElasticityMaterials TestingPrinting, Three-DimensionalAgedBiomechanical PhenomenaHumansMaleMechanical TestsAdditive manufacturingBiomechanicsBoneCadavericClavicle

Identifiers

PMID39413544
PMCPMC11560652

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.