ArticleJournal of the International Society for Respiratory Protection2023
Modifying NIOSH's Manikin Fit Evaluation Method to Match Fit Testing with Human Subjects.
Article in Journal of the International Society for Respiratory Protection, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
A manikin fit test method developed by the Center for Disease Control and Prevention's (CDC) National Institute of Occupational Safety and Health (NIOSH) has been proposed as an alternative to fit testing with human subjects. The advantages of a manikin fit test method over actual fit testing are that it does not require human subjects which can be resource intensive, and hence easier to implement. At the beginning of coronavirus 2019 (COVID-19) pandemic, although early studies showed that manikin fit can be maintained after several decontamination cycles, real world evidence obtained using human subjects revealed that the N95 respirators failed only after a few decontamination cycles. The goal of this article was to make modifications to the NIOSH's manikin fit-test method so it can mimic real world performance of N95 respirators better. After making modifications to this method, we then investigated the effect of long-term wear after donning of the respirators, repeated donning and doffing, as well as decontamination methods (i.e. autoclaving and microwave generated steam) on the fit factor. Averaging the overall manikin fit factor across all scenarios, our modified method overpredicted overall fit factor by only 7 % and 14 % compared to adult human subjects using a breathing routine that included simulated heavy breathing rates of 85, and 70 Liters/minute, respectively. In addition, a constant flow produced similar results as cyclic flow using a breathing simulator. The modified test method also offered the following additional insights into reuse of respirators during future pandemics - when reused within a single work shift, more than 5 donnings should be avoided; and microwave generated steam may be a more viable option for decontaminating N95 respirators compared to autoclaving for a single decontamination cycle.
Indexed as
Identifiers
39411447PMC11478269What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.