In Vitro Investigation Using a New Biomechanical Force-Torque Analysis System: Comparison of Conventional and CAD/CAM-Fixed Orthodontic Retainers.

Francesca Thaden, Linus Hötzel, Hisham Sabbagh, Matthias Mertmann, Andrea Wichelhaus

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Francesca ThadenDepartment of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany.
Linus HötzelDepartment of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany.ORCID 0009-0005-5179-3818
Hisham SabbaghDepartment of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany.ORCID 0000-0002-9535-6901
Matthias MertmannDepartment of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany.
Andrea WichelhausDepartment of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany.ORCID 0000-0001-8489-167X

Funding

Friedrich Bauer Stiftung 74/19
6 · The paper itself

Abstract

(1) Background: After more than a decade since their first description, Inadvertent Tooth Movements (ITMs) remain an adverse effect of orthodontic retainers without a clear etiology. To further investigate the link between ITMs and the mechanical properties of different retainers, the response upon vertical loading was compared in three retainer types (two stainless steel and one nickel-titanium). The influence of different reference teeth was also considered. (2) Methods: Three retainers (R1, R2, R3) were tested in a newly developed biomechanical analysis system (FRANS). They were bonded to 3D-printed models of the lower anterior jaw and vertically displaced up to 0.3 mm. Developing forces and moments were recorded at the center of force. (3) Results: The vertical displacement caused vertical forces (Fz) and labiolingual moments (My) to arise. These were highest in the lateral incisors (up to 2.35 ± 0.59 N and 9.27 ± 5.86 Nmm for R1; 1.69 ± 1.06 N and 7.42 ± 2.65 Nmm for R2; 3.28 ± 1.73 N and 15.91 ± 9.71 Nmm for R3) for all analyzed retainers and with the R3 retainer for all analyzed reference teeth, while the lowest Fz and My values were recorded with the R1 retainer. (4) Conclusions: Displacements of 0.2 mm and larger provided forces and moments which could be sufficient to cause unwanted torque movements, such as ITMs, in all analyzed retainers. Clinicians must be mindful of these risks and perform post-treatment checkups on patients with retainers of all materials.

Indexed as

biomechanical phenomenaforceorthodontic retainer adverse effectsorthodonticsretainertorque

Identifiers

PMID39410487
PMCPMC11477892

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.