ArticlePolymers2024
Robust Strain Sensor with High Sensitivity Based on Polymer-Encapsulated Microfiber Mach-Zehnder Interferometer.
Article in Polymers, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
A robust strain sensor is demonstrated based on a microfiber Mach-Zehnder interferometer (MMZI) encapsulated by the polymer polydimethylsiloxane (PDMS). Benefiting from the low Young's modulus of PDMS, both a robust structure and high sensitivity can be realized based on three different encapsulations. In the experiment, the proposed sensors are fabricated and tested with strain sensitivities ranging from -20.95 pm/με to 127.00 pm/με within the wavelength range of 1200-1650 nm. Compared with the bare MMZI sensor, at least one order of magnitude higher sensitivity is reached. To further evaluate the performance of the sensor, the dependences of sensitivity on probing wavelength and the different types and quantities of polymers used in encapsulation are discussed. Results show that the sensitivity of the sensor will increase with the probing wavelength. The type and quantity of polymer used are also very critical to sensitivity. Additionally, a response time of 24.72 ms can be reached. Good recoverability and repeatability of the sensor are also demonstrated by repeated experiments. The strain sensor demonstrated here shows the advantages of simple fabrication, robust structure, high and tunable sensitivity, fast response, good recoverability and repeatability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.