Evidence map›Paper›PMID 39407004›Full record

Observational studyAesthetic plastic surgery2024

Short-Term Outcomes of High-Density Porous Polyethylene Orthoses for Chin and Gonial Angle Augmentation.

Jorge Henrique Fernandes da Rocha, Fernanda Cristina Poscai Ribeiro, Gabriela Duarte Da Silva, Raquel Fernandes de Alcantara Giraud, Rodrigo Siqueira Lima, Fernando Platania, Marcilio Abracos Jorge

Abstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in Aesthetic plastic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jorge Henrique Fernandes da RochaDepartment of Surgery, Medical School, Western São Paulo University (UNOESTE), Guarujá, São Paulo, Brazil.
Fernanda Cristina Poscai RibeiroDepartment of Internal Medicine, Medical School, Western São Paulo University (UNOESTE), Guarujá, São Paulo, Brazil. fernandaposcai@gmail.com.ORCID 0000-0002-8824-3490
Gabriela Duarte Da SilvaDepartment of Surgery, Medical School, Western São Paulo University (UNOESTE), Guarujá, São Paulo, Brazil.
Raquel Fernandes de Alcantara GiraudDepartment of Surgery, Medical School, Western São Paulo University (UNOESTE), Guarujá, São Paulo, Brazil.
Rodrigo Siqueira LimaDepartment of Surgery, Medical School, Western São Paulo University (UNOESTE), Guarujá, São Paulo, Brazil.
Fernando PlataniaDepartment of Surgery, Medical School, Western São Paulo University (UNOESTE), Guarujá, São Paulo, Brazil.
Marcilio Abracos JorgeDepartment of Surgery, Medical School, Western São Paulo University (UNOESTE), Guarujá, São Paulo, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The high-density porous polyethylene implants are used in chin and gonial angle augmentation surgeries. These implants are valued for their biocompatibility and ease of integration with tissues, particularly in correcting retrognathia and mandibular hypoplasia. The research aimed to detail the epidemiological profile, feasibility, outcomes, and complications associated with these procedures. METHODOLOGY: This retrospective observational study evaluated 100 patients over 18 years. Data on age, sex, aesthetic complaints, surgery types, and postoperative complications were collected and analyzed using the two-proportion z-test and descriptive statistics in RStudio 4.3.3. All patients with neuropraxia underwent neurosensory evaluation.

resultsThe average age was 35.92 years for males and 33.71 years for females, with a male predominance (76%). Aesthetic complaints were prevalent in 72% of patients (p < 0.01). Chin surgery was performed on 56% of patients, jaw angle surgery on 17%, and both on 39%. Complications included one case of suture dehiscence, three wound infections, and four transient cases of paresthesia, all resolving within 30 days. Overall, patient satisfaction with outcomes was high.

conclusionHigh-density porous polyethylene implants proved effective and safe in enhancing facial aesthetics and correcting mandibular deformities. Further research should focus on long-term outcomes to consolidate these findings. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Indexed as

PolyethyleneProstheses and ImplantsAdultChinCohort StudiesEstheticsFemaleFollow-Up StudiesHumansMaleMiddle AgedPatient SatisfactionPorosityProsthesis DesignRetrospective StudiesRisk AssessmentPolyethyleneAlloplastic materialChin augmentationGonial angle implantsHigh-density polyethylene

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.