Evidence map›Paper›PMID 39404978›Full record

ArticleInternational journal of implant dentistry2024

Achieving automated and high-precision in situ analysis of the dimensional accuracy and dynamic deformation of 3D-printed surgical templates: an in vitro study.

Lixing He, Bowen Qin, Rongrong Zhu, Yunxian Liu, Boya Xu, Zhe Li, Liangzhi Du

Abstract read
In one paragraph

Article in International journal of implant dentistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lixing He *Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710004, China.
Bowen Qin *National & Local Joint Engineering Research Center of Biodiagnosis and Biotherapy, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
Rongrong Zhu *Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710004, China.
Yunxian LiuKey Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710004, China.
Boya XuKey Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710004, China.
Zhe LiKey Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710004, China. drlizhe@126.com.
Liangzhi DuKey Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, 710004, China. drliangzhidu@126.com.

Funding

Key Research and Development Projects of Shaanxi Province 2023-YBSF-220Key Research and Development Projects of Shaanxi Province,China 2023-YBSF-193National Natural Science Foundation of China 82301155
6 · The paper itself

Abstract

purposeTo demonstrate the viability of a coordinate-measuring machine (CMM) for the geometric analysis of 3D printed surgical templates.

methodsThe template was designed and modified by adding 18 cylindrical landmarks for CMM test and then classified into five groups according to the slicing software and resins (opaque and transparent): Streamflow-O, Streamflow-T, Shapeware-T, Rayware-T and Polydevs-T (N = 3). Three standing times (0 w, 1 w, and 2 w) were included to observe possible deformation. All the measurements were performed automatically by the CMM through a preset program. The Euclidian distance (dxyz) was regarded as the representation of global dimension accuracy, and displacements in the x-, y-, and z-axes were also calculated.

resultsThe average dxyz values of Streamflow-O, Streamflow-T, Shapeware-T, Rayware-T and Polydev-T are 32.6 μm, 31.3 μm, 56.4 μm, 96.4 μm, and 55.3 μm, respectively. Deviations were mainly induced by the upward bending of the free end region (positive direction of the z-axis). Different resins did not have a significant influence on the dimensional accuracy. Moreover, deformation appeared to be negligible after 2 weeks of storage, and the z-axis displacements were only approximately 30 μm at week 1 and 10 μm at week 2.

conclusionsThe deviations of the DLP-printed template are induced mainly by z-axis displacements and are determined by the processing accuracy. After 2 weeks, the dimensional stabilities of these templates are reliable, which is encouraging for clinicians. Moreover, the CMM is preliminarily demonstrated to be a feasible tool for achieving automated geometric analysis of surgical templates.

Indexed as

Printing, Three-DimensionalHumansIn Vitro TechniquesSoftware3D printingCoordinate-measuring machineDeformationDimensional accuracySurgical template

Identifiers

PMID39404978
PMCPMC11480287

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.