Evidence map›Paper›PMID 39404711›Full record

ArticleACS sensors2024

Inclusive and Accurate Clinical Diagnostics Using Intelligent Computation and Smartphone Imaging.

Jisen Chen, Dajun Zhao, Hai-Wei Shi, Qiaolian Duan, Pawel Jajesniak, Yunxin Li, Wei Shen, Jinghui Zhang, Julien Reboud, Jonathan M Cooper and 1 more

Abstract read
In one paragraph

Article in ACS sensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Jisen ChenSchool of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212003, PR China.
Dajun ZhaoSchool of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212003, PR China.
Hai-Wei ShiJiangsu Institute for Food and Drug Control, Nanjing, Jiangsu 210019, PR China.
Qiaolian DuanJiangsu Institute for Food and Drug Control, Nanjing, Jiangsu 210019, PR China.ORCID 0000-0003-1026-1055
Pawel JajesniakSchool of Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom.
Yunxin LiSchool of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212003, PR China.
Wei ShenSchool of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212003, PR China.ORCID 0000-0001-8159-5728
Jinghui ZhangSchool of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212003, PR China.ORCID 0000-0003-1630-6250
Julien ReboudSchool of Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom.ORCID 0000-0002-6879-8405
Jonathan M CooperSchool of Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom.ORCID 0000-0002-2358-1050
Sheng TangSchool of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212003, PR China.ORCID 0000-0002-2206-7981

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Smartphone-based colorimetry has been widely applied in clinical analysis, although significant challenges remain in its practical implementation, including the need to consider biases introduced by the ambient imaging environment, which limit its potential within a clinical decision pathway. In addition, most commercial devices demonstrate variability introduced by manufacturer-to-manufacturer differences. Here, we undertake a systematic characterization of the potential imaging interferences that lead to this limited performance in conventional smartphones and, in doing so, provide a comprehensive new understanding of smartphone color imaging. Through derivation of a strongly correlated parameter for sample quantification, we enable real-time imaging, which for the first time, takes the first steps to turning the mobile phone camera into an analytical instrument - irrespective of model, software, and the operating systems used. We demonstrate clinical applicability through the imaging of patients' skin, enabling rapid and convenient diagnosis of cyanosis and measurement of local oxygen concentration to a level that unlocks clinical decision-making for monitoring cardiovascular disease and anemia. Importantly, we show that our solution also accounts for the differences in individuals' skin tones as measured across the Fitzpatrick scale, overcoming potential clinically significant errors in current optical oximetry.

Indexed as

SmartphoneColorimetryHumansOximetryartificial intelligencecardiovascular diseasediagnosisoximetryskin tonesmartphone imaging

Identifiers

PMID39404711
PMCPMC11519924

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.