Evidence map›Paper›PMID 39403885›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2024

Thermally Drawn Polymeric Catheters for MR-Guided Cardiovascular Intervention.

Mohamed E M K Abdelaziz, Libaihe Tian, Thomas Lottner, Simon Reiss, Timo Heidt, Alexander Maier, Klaus Düring, Constantin von Zur Mühlen, Michael Bock, Eric Yeatman and 2 more

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Thermally Drawn Polymeric Catheters for MR-Guided Cardiovascular Intervention.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Mohamed E M K AbdelazizThe Hamlyn Centre for Robotic Surgery, Imperial College London, London, SW7 2AZ, UK.ORCID 0000-0003-2763-8998
Libaihe TianThe Hamlyn Centre for Robotic Surgery, Imperial College London, London, SW7 2AZ, UK.ORCID 0000-0003-3734-4969
Thomas LottnerDepartment of Diagnostic and Interventional Radiology, Medical Physics, Faculty of Medicine, University of Freiburg, 79106, Freiburg, Germany.ORCID 0000-0003-3215-7582
Simon ReissDepartment of Diagnostic and Interventional Radiology, Medical Physics, Faculty of Medicine, University of Freiburg, 79106, Freiburg, Germany.ORCID 0000-0003-2449-1679
Timo HeidtDepartment of Cardiology and Angiology, University Heart Center Freiburg - Bad Krozingen, Faculty of Medicine, University of Freiburg, 79106, Freiburg, Germany.ORCID 0000-0002-9607-7963
Alexander MaierDepartment of Cardiology and Angiology, University Heart Center Freiburg - Bad Krozingen, Faculty of Medicine, University of Freiburg, 79106, Freiburg, Germany.ORCID 0000-0003-0200-7495
Klaus DüringMaRVis Interventional GmbH, 82467, Garmisch-Partenkirchen, Germany.
Constantin von Zur MühlenDepartment of Cardiology and Angiology, University Heart Center Freiburg - Bad Krozingen, Faculty of Medicine, University of Freiburg, 79106, Freiburg, Germany.
Michael BockDepartment of Diagnostic and Interventional Radiology, Medical Physics, Faculty of Medicine, University of Freiburg, 79106, Freiburg, Germany.ORCID 0000-0001-9720-3506
Eric YeatmanDepartment of Electrical and Electronic Engineering, Faculty of Engineering, Imperial College London, London, SW7 2AZ, UK.ORCID 0000-0003-0487-2693
Guang-Zhong YangInstitute of Medical Robots, Shanghai Jiao Tong University, Shanghai, 200240, China.
Burak TemelkuranThe Hamlyn Centre for Robotic Surgery, Imperial College London, London, SW7 2AZ, UK.ORCID 0000-0003-2390-5091

Funding

Deutsche ForschungsgemeinschaftDeutsche Forschungsgemeinschaft 492563001Deutsche Forschungsgemeinschaft #494790146Engineering and Physical Sciences Research Council EP/P012779
6 · The paper itself

Abstract

Cardiovascular diseases (CVDs), including congenital heart diseases (CHD), present significant global health challenges, emphasizing the need for safe and effective treatment modalities. Fluoroscopy-guided endovascular interventions are widely utilized but raise concerns about ionizing radiation, especially in pediatric cases. Magnetic resonance imaging (MRI) offers a radiation-free alternative with superior soft tissue visualization and functional insights. However, the lack of compatible instruments remains a major obstacle. An adapted thermal drawing platform that enables low-cost and rapid prototyping of instruments for MR-guided endovascular interventions is introduced. This platform is demonstrated through the development of two exemplary catheter systems: a tendon-driven steerable catheter with helical lumina and an active tracking Tiger-shaped catheter with an embedded coaxial wire. These catheters exhibit mechanical properties comparable to commercial counterparts and show promising outcomes in both in vitro and in vivo feasibility testing. This scalable thermal drawing platform addresses the limitations of existing manufacturing approaches and facilitates the exploration of diverse designs, potentially accelerating advancements in catheter technologies for MR-guided cardiovascular interventions.

Indexed as

Equipment DesignAnimalsCardiovascular DiseasesCathetersEndovascular ProceduresHumansMagnetic Resonance ImagingMagnetic Resonance Imaging, InterventionalPolymersPolymerscardiovascular interventionscatheterendovascular interventionsMRIthermal drawings

Identifiers

PMID39403885
PMCPMC11615795

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.