Evidence map›Paper›PMID 39403557›Full record

ArticleDEN open2025

A novel puzzle ring replacement technique of a lumen-apposing metal stent with a double-pigtail plastic stent to prevent walled-off necrosis recurrence (with video).

Shuntaro Mukai, Atsushi Sofuni, Takayoshi Tsuchiya, Reina Tanaka, Ryosuke Tonozuka, Kenjiro Yamamoto, Yukitoshi Matsunami, Kazumasa Nagai, Hiroyuki Kojima, Hirohito Minami and 2 more

Abstract read
In one paragraph

Article in DEN open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Shuntaro MukaiDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.ORCID https://orcid.org/0000-0001-5737-620X
Atsushi SofuniDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.
Takayoshi TsuchiyaDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.
Reina TanakaDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.
Ryosuke TonozukaDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.
Kenjiro YamamotoDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.
Yukitoshi MatsunamiDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.
Kazumasa NagaiDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.
Hiroyuki KojimaDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.
Hirohito MinamiDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.
Kyoko AsanoDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.
Takao ItoiDepartment of Gastroenterology and Hepatology Tokyo Medical University Tokyo Japan.ORCID https://orcid.org/0000-0002-9433-8437

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Replacing a lumen-apposing metal stent (LAMS) with a double-pigtail plastic stent (DPS) after treatment for walled-off necrosis contributes to the prevention of recurrence. However, the success rate is not very high. To overcome this issue, we devised a novel stent-replacement technique. In the final treatment procedure, a 7-F DPS was placed in the lumen of the LAMS. Subsequently, the walled-off necrosis shrank, and granulation formed over the pigtail portion, which fixed the DPS. The LAMS alone was removed with grasping forceps, leaving the DPS in the lumen of the LAMS (i.e., a puzzle-ring technique; direct or rotary removal technique). Between August 2021 and August 2023, 18 patients were evaluated for recurrence prevention using this novel technique (median duration of LAMS placement, 37 days). In 17 patients (94.4%), the LAMS was successfully replaced with a 7-F DPS (direct technique 14, rotary technique 3; median removal procedure time, 3 min). No recurrence was observed during the median observation period of 385 days. Before using this technique (April 2012 to August 2022), the technical success rate of replacement of LAMS with 7-F DPS was significantly lower (61.8% [42/68,

Indexed as

double‐pigtail plastic stentendoscopic ultrasound‐guided transluminal pancreatic fluid collection drainagelumen‐apposing metal stentnecrotizing pancreatitiswalled‐off necrosis

Identifiers

PMID39403557
PMCPMC11472131

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.