Evidence map›Paper›PMID 39402798›Full record

ArticleMagnetic resonance in medicine2025

Phase contrast MRI with minimized background phase errors.

Michael Loecher, Daniel B Ennis

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Michael LoecherDepartment of Radiology, Stanford University, Stanford, California, USA.ORCID 0000-0002-6533-1113
Daniel B EnnisDepartment of Radiology, Stanford University, Stanford, California, USA.

Funding

Enabling the Next Generation of High Performance Pediatric Whole Body MR ImagingU01EB029427 · NIBIB · STANFORD UNIVERSITY · PI LUSTIG, MICHAEL, PAULY, JOHN M. · 2020 to 2023
$3.4M
Using Atrial Mechanics To Identify Fibrosis In Patients with Atrial FibrillationR01HL152256 · NHLBI · STANFORD UNIVERSITY · PI ENNIS, DANIEL B · 2020 to 2023
$2.8M
A New Framework for Understanding the Mechanisms of Diastolic DysfunctionR01HL131823 · NHLBI · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI ENNIS, DANIEL B · 2017 to 2020
$2.3M
Fast and Accurate Cardiovascular MRI with Hyper 4D-FlowR01HL171515 · NHLBI · STANFORD UNIVERSITY · PI Daniel B Ennis, Shreyas S Vasanawala · 2024 to 2026
$1.9M
NHLBI NIH HHS R01 HL131823NHLBI NIH HHS R01 HL152256NHLBI NIH HHS R01 HL171515NIBIB NIH HHS U01 EB029427
6 · The paper itself

Abstract

purposePhase contrast MRI (PC-MRI) is used clinically to measure velocities in the body, but systematic background phase errors caused by magnetic field imperfections corrupt the velocity measurements with offsets that limit clinical utility. This work aims to minimize systematic background phase errors in PC-MRI, thereby maximizing the accuracy of velocity measurements.

methodsThe MRI scanner's background phase errors from eddy currents and mechanical oscillations were modeled using the gradient impulse response function (GIRF). Gradient waveforms were then numerically optimized using the GIRF to create pulse sequences that minimize the background phase errors. The pulse sequences were tested in a static phantom where the predicted response could be compared directly to the measured background velocity. The optimized acquisitions were then tested in human subjects, where flow rates and background errors were compared to conventional PC-MRI.

resultsWhen using the GIRF-optimized gradient waveforms, the predicted background phase was within 0.6 [95% CI = -3.4, 5.4] mm/s of the measured background phase in a static phantom. Excellent agreement was seen for in vivo blood flow values (flow rate agreement

conclusionThis work shows that using a GIRF to model the effects of magnetic field imperfections combined with numerically optimized gradient waveforms enables PC-MRI waveforms to be designed to produce a minimal background phase in the most time-efficient manner. The methodology could be adapted for other MRI sequences where similar magnetic field errors affect measurements.

Indexed as

Magnetic Resonance ImagingPhantoms, ImagingAlgorithmsArtifactsBlood Flow VelocityHumansImage Processing, Computer-AssistedMagnetic FieldsReproducibility of Resultsbackground phasegradient impulse responsegradient optimizationphase contrast

Identifiers

PMID39402798
PMCPMC11870205

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.