Deep Learning-Based Estimation of Radiographic Position to Automatically Set Up the X-Ray Prime Factors.

C F Del Cerro, R C Giménez, J García-Blas, K Sosenko, J M Ortega, M Desco, M Abella

Erratum issuedAbstract read
In one paragraph

Article in Journal of imaging informatics in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

C F Del CerroDept. Bioingeniería, Universidad Carlos III de Madrid, Leganés, Madrid, Spain.ORCID http://orcid.org/0000-0002-0112-9709
R C GiménezDept. Bioingeniería, Universidad Carlos III de Madrid, Leganés, Madrid, Spain.ORCID http://orcid.org/0000-0002-3090-126X
J García-BlasDept. de Informática, Universidad Carlos III de Madrid, Madrid, Spain.ORCID http://orcid.org/0000-0003-1452-1918
K SosenkoSociedad Española de Electromedicina y Calidad S.A. (SEDECAL), Madrid, Spain.
J M OrtegaSociedad Española de Electromedicina y Calidad S.A. (SEDECAL), Madrid, Spain.ORCID http://orcid.org/0009-0005-1492-3513
M DescoDept. Bioingeniería, Universidad Carlos III de Madrid, Leganés, Madrid, Spain. desco@hggm.es.ORCID http://orcid.org/0000-0003-0989-3231
M AbellaDept. Bioingeniería, Universidad Carlos III de Madrid, Leganés, Madrid, Spain. mabella@ing.uc3m.es.ORCID http://orcid.org/0000-0002-4847-7233

Funding

Horizon 2020 801091Instituto de Salud Carlos III PMPTA22/00118Instituto de Salud Carlos III PMPTA22/00121Ministerio de Ciencia e Innovación PDC2021-121656-I00
6 · The paper itself

Abstract

Radiation dose and image quality in radiology are influenced by the X-ray prime factors: KVp, mAs, and source-detector distance. These parameters are set by the X-ray technician prior to the acquisition considering the radiographic position. A wrong setting of these parameters may result in exposure errors, forcing the test to be repeated with the increase of the radiation dose delivered to the patient. This work presents a novel approach based on deep learning that automatically estimates the radiographic position from a photograph captured prior to X-ray exposure, which can then be used to select the optimal prime factors. We created a database using 66 radiographic positions commonly used in clinical settings, prospectively obtained during 2022 from 75 volunteers in two different X-ray facilities. The architecture for radiographic position classification was a lightweight version of ConvNeXt trained with fine-tuning, discriminative learning rates, and a one-cycle policy scheduler. Our resulting model achieved an accuracy of 93.17% for radiographic position classification and increased to 95.58% when considering the correct selection of prime factors, since half of the errors involved positions with the same KVp and mAs values. Most errors occurred for radiographic positions with similar patient pose in the photograph. Results suggest the feasibility of the method to facilitate the acquisition workflow reducing the occurrence of exposure errors while preventing unnecessary radiation dose delivered to patients.

Indexed as

Deep LearningRadiographyHumansRadiation DosageX-RaysClassificationDeep learningPrime factorsRadiographic positionRadiography

Identifiers

PMID39402356
PMCPMC12092909

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.