ArticleScientific reports2024
Clinical value of transperineal ultrasound in evaluating the effects of different delivery methods on the primipara pelvic floor structure and function.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Development and Validation of a Predictive Model for Postpartum Stress Urinary Incontinence: Factors and Assessment in a Single-Center Prospective Study.International urogynecology journal · 2026Article
- The influence of neonatal birth weight on postpartum pelvic floor function in primiparas.Medicine · 2026Article
- Multiparametric comparative assessment of surgical efficacy in patients with SUI and POP versus normal controls.Scientific reports · 2026Article
- Automated transperineal ultrasound analysis using deep learning for pelvic floor dysfunction assessment after total hysterectomy.Frontiers in oncology · 2026Article
- Transperineal combined two- and three-dimensional ultrasound evaluation of the effects of different delivery methods on levator ani muscles and pelvic organ prolapse.Quantitative imaging in medicine and surgery · 2025Article
- A Rare Case of Severe Pelvic Organ Prolapse with Massive Perineal Hernia in a Nulliparous Woman: A Case Report and Literature Review.Diagnostics (Basel, Switzerland) · 2025Article
- Development and validation of a risk prediction model for postpartum urinary incontinence in primiparas using clinical and pelvic floor ultrasound characteristics.Frontiers in medicine · 2025Article
- Effects of Functional Magnetic Stimulation Combined with Pelvic Floor Muscle Training on Cerebral Hemodynamics and Brain Functional Connectivity in Women with Postpartum Pelvic Floor Dysfunction: A Randomized Controlled Trial.International journal of women's health · 2025Article
- Dynamic biomechanical equilibrium in pelvic organ prolapse: from mechanistic insights to precision reconstruction.Frontiers in medicine · 2025Article
Corrections and comments
- Erratum issued
Authors and funding
4 authors.
Funding
Abstract
To evaluate the effects of different delivery methods on the pelvic floor structure and function among primiparas by transperineal ultrasound, with a view to providing guidance for early postpartum intervention. Primiparas who underwent postpartum examination with transperineal ultrasound were recruited. Subjects were divided according to mode of delivery (vaginal and cesarean delivery). General information (including age, pre-pregnancy BMI and neonatal weight) were collected, and transperineal ultrasound was performed to measure such indicators as the levator hiatus areas in resting, constrictive anal and maximum Valsalva states, the posterior vesicourethral angles and distances between vesical neck and posterior inferior margin of pubic symphysis in resting and maximum Valsalva states, as well as the vesical neck mobility and urethral rotation angle in maximum Valsalva state. The inter-group differences in ultrasound indicators between the resting and Valsalva states were compared to analyze the postpartum incidences of pelvic floor dysfunctions like stress urinary incontinence, urethral funnel formation, bladder prolapse and uterine prolapse in primiparas. The levator hiatus areas in resting, constrictive anal and maximum Valsalva states were all larger in the vaginal delivery group than in the cesarean delivery group (P < 0.05). Compared to the cesarean delivery group, the vaginal delivery group exhibited larger posterior vesicourethral angles in resting and maximum Valsalva states (P < 0.05). The distances between vesical neck and posterior inferior margin of pubic symphysis were greater in the cesarean delivery group than in the vaginal delivery group at both resting and maximum Valsalva, with that at maximum Valsalva showing significant inter-group difference (P < 0.05). The vaginal delivery group exhibited greater vesical neck mobility and urethral rotation angle at maximum Valsalva compared to the cesarean delivery group (P < 0.05). The incidences of stress urinary incontinence, urethral funnel formation, bladder prolapse and uterine prolapse were all higher in the vaginal delivery group than in the cesarean delivery group, with the stress urinary incontinence and bladder prolapse incidences showing significant inter-group differences (P < 0.05). With transperineal ultrasound, various pelvic floor indicators of primiparas can be clearly measured and, through these ultrasound indicators, the effects of different delivery methods on the pelvic floor function can be evaluated, which is conducive to early clinical detection and intervention of postpartum pelvic floor dysfunctions, thus facilitating the early postpartum treatment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.