Evidence map›Paper›PMID 39400830›Full record

ArticleAdvances in experimental medicine and biology2024

Fabrication of Tuneable Tissue-Mimicking Phantom for Optical Methods.

Tong Li, Aldo Di Costanzo Mata, Alexander Kalyanov, Martin Wolf, Jingjing Jiang

Abstract read
PubMed Publisher
In one paragraph

Article in Advances in experimental medicine and biology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tong LiBiomedical Optics Research Laboratory (BORL), Department of Neonatology, University of Zurich and University Hospital Zurich, Zürich, Switzerland. tong.li@usz.ch.
Aldo Di Costanzo MataBiomedical Optics Research Laboratory (BORL), Department of Neonatology, University of Zurich and University Hospital Zurich, Zürich, Switzerland.
Alexander KalyanovBiomedical Optics Research Laboratory (BORL), Department of Neonatology, University of Zurich and University Hospital Zurich, Zürich, Switzerland.
Martin WolfBiomedical Optics Research Laboratory (BORL), Department of Neonatology, University of Zurich and University Hospital Zurich, Zürich, Switzerland.
Jingjing JiangBiomedical Optics Research Laboratory (BORL), Department of Neonatology, University of Zurich and University Hospital Zurich, Zürich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTissue mimicking optical phantoms are commonly used to calibrate or validate the performance of near-infrared spectroscopy or tomography. Human tissue is not only irregular in shape, but also exhibits dynamic behaviour, which can cause changes in optical properties. However, existing phantoms lack complex structures and/or continuously varying optical properties.

aimThe project aimed to design, fabricate and characterise a novel phantom system for testing near-infrared imaging devices. MATERIAL AND

methodsWe designed a dynamic tissue-mimicking phantom platform which features arbitrary internal shapes and variable optical properties. The solid part of phantom was made of silicone material with absorbing and scattering properties similar to the brain. We printed a semi-ellipsoidal sphere (a major axis = 20 mm and a minor axis = the third axis = 12 mm) using a water-soluble material polyvinyl alcohol (PVA). The shape was placed at the depth of 5 mm in the silicone bulk. The desired internal hollow structure was formed after curing and submerging the phantom in water. The liquid part contained dyes and Intralipid. The optical properties within the internal shape were adjusted by injecting the liquid solutions of varying dye concentrations with a syringe pump at a constant rate. The phantom was measured by a frequency domain near-infrared spectroscopy (FD NIRS) and imaged by a time domain near-infrared optical tomography (TD NIROT). RESULTS AND DISCUSSION: A dynamic phantom system with a complex internal structure and varying optical properties was created. Changes in light intensity were detected by the FD NIRS. The internal structure of this phantom was accurately recovered by NIROT image reconstruction.

conclusionWe successfully developed a novel phantom system with an internal complex shape and continuously adjustable optical properties. This phantom was accurately imaged using NIROT, and the changing light intensity was detected by NIRS. It is a valuable tool for validating optical technologies.

Indexed as

Phantoms, ImagingSpectroscopy, Near-InfraredEquipment DesignHumansOptical ImagingPolyvinyl AlcoholSiliconesTomography, OpticalPolyvinyl AlcoholSiliconesDynamic phantomsNear-infrared spectroscopyNear-infrared tomographyOptical devicesOptical phantoms

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked