Quantitative CT imaging and radiation-absorbed dose estimations of

Chiron Morsink, Nienke Klaassen, Gerrit van de Maat, Milou Boswinkel, Alexandra Arranja, Robin Bruggink, Ilva van Houwelingen, Irene Schaafsma, Jan Willem Hesselink, Frank Nijsen and 1 more

Abstract read
In one paragraph

Article in European radiology experimental, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Chiron MorsinkDepartment of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, PO Box 80154, 3508 TD, Utrecht, The Netherlands. n.c.morsink@uu.nl.ORCID http://orcid.org/0000-0001-5467-6979
Nienke KlaassenDepartment of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands.
Gerrit van de MaatQuirem Medical B.V., 8418 AH, Deventer, The Netherlands.
Milou BoswinkelDepartment of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands.
Alexandra ArranjaQuirem Medical B.V., 8418 AH, Deventer, The Netherlands.
Robin Bruggink3D Lab, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands.
Ilva van HouwelingenQuirem Medical B.V., 8418 AH, Deventer, The Netherlands.
Irene SchaafsmaDepartment of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, PO Box 80154, 3508 TD, Utrecht, The Netherlands.
Jan Willem HesselinkDepartment of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, PO Box 80154, 3508 TD, Utrecht, The Netherlands.
Frank NijsenDepartment of Medical Imaging, Radboud Institute for Health Sciences, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands.
Bas van NimwegenDepartment of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, PO Box 80154, 3508 TD, Utrecht, The Netherlands.

Funding

Stichting voor de Technische Wetenschappen 15499
6 · The paper itself

Abstract

backgroundMicrobrachytherapy enables high local tumor doses sparing surrounding tissues by intratumoral injection of radioactive holmium-166 microspheres (

methodsTwo scanners were calibrated for Ho detection using phantoms and multiple settings. Quantification was evaluated in five phantoms and seven canine patients using subtraction and thresholding including influences of the target tissue, injected amounts, acquisition parameters, and quantification volumes. Radiation-absorbed dose estimation was implemented using a three-dimensional

resultsCT calibration showed a near-perfect linear relation between radiodensity (HU) and Ho concentrations for all conditions, with differences between scanners. Ho detection during calibration was higher using lower tube voltages, soft-tissue kernels, and without a scanner detection limit. The most accurate Ho recovery in phantoms was 102 ± 11% using a threshold of mean tissue HU + (2 × standard deviation) and in patients 98 ± 31% using a 100 HU threshold. Thresholding allowed better recovery with less variation and dependency on the volume of interest compared to the subtraction of a single HU reference value. Corresponding doses and histograms were successfully generated.

conclusionCT quantification and dosimetry of RELEVANCE STATEMENT: Image-guided holmium-166 microbrachytherapy currently lacks reliable quantification and dosimetry on CT to ensure treatment safety and efficacy, while it is the only imaging modality capable of quantifying high in vivo holmium concentrations. KEY POINTS: Local injection of

Indexed as

HolmiumMicrospheresPhantoms, ImagingRadioisotopesTomography, X-Ray ComputedAnimalsDogsMonte Carlo MethodRadiation DosageHolmiumHolmium-166RadioisotopesBrachytherapyDosimetryHolmium-166Monte Carlo methodTomography (x-ray computed)

Identifiers

PMID39400769
PMCPMC11473764

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.