Evidence map›Paper›PMID 39400610›Full record

ArticleNeurosurgical review2024

Feasibility and radial artery occlusion rate of sheathless distal transradial access using balloon guide catheters.

Koki Onodera, Masataka Yoshimura, Kuya Azekami, Ryutaro Kimura, Noriyuki Yahagi, Ryuta Kajimoto, Shinya Kohyama

Abstract read
PubMed Publisher
In one paragraph

Article in Neurosurgical review, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Feasibility of the distal transradial approach with an 8-Fr balloon guide catheter for neurointerventional procedures.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  4. A novel peel-away sheath technique for sheathless transradial use of 8 Fr balloon guide catheter.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Koki OnoderaDepartment of Endovascular Neurosurgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka City, Saitama Prefecture, 350-1298, Japan. onoderakoki@gmail.com.
Masataka YoshimuraDepartment of Endovascular Neurosurgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka City, Saitama Prefecture, 350-1298, Japan.
Kuya AzekamiDepartment of Endovascular Neurosurgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka City, Saitama Prefecture, 350-1298, Japan.
Ryutaro KimuraDepartment of Endovascular Neurosurgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka City, Saitama Prefecture, 350-1298, Japan.
Noriyuki YahagiDepartment of Endovascular Neurosurgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka City, Saitama Prefecture, 350-1298, Japan.
Ryuta KajimotoDepartment of Endovascular Neurosurgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka City, Saitama Prefecture, 350-1298, Japan.
Shinya KohyamaDepartment of Endovascular Neurosurgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka City, Saitama Prefecture, 350-1298, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Distal transradial access (dTRA), performed through an anatomical snuffbox, minimizes post-procedural burdens of endovascular treatments. However, despite the benefits of balloon-guide catheters (BGCs), their use in dTRA is limited by their small radial artery diameter. Herein, we evaluated the feasibility and radial artery occlusion (RAO) rate of 8Fr BGCs used in sheathless dTRA. This retrospective study reviewed patients treated with sheathless dTRA using an 8Fr Optimo at a single center between July 2023 and May 2024. dTRA procedures were performed under general anesthesia in patients not requiring urgent treatment. The RAO was assessed using ultrasonography 24 h after the procedure. The demographic and procedural characteristics were compared between the radial artery patency and occlusion groups. Of 170 patients, 50 underwent dTRA, and 43 (86%) completed the procedure. RAO occurred in 12/43 (28%) patients with dTRA. Univariate and receiver operating characteristic curve analyses demonstrated that the median radial artery diameter was significantly smaller in the RAO group (P < 0.001), with an optimal cut-off value of 2.4 mm to predict RAO. Complications included minor cerebral ischemia in two patients, but no severe ischemia was observed. Sheathless dTRA using an 8Fr Optimo BGC is feasible, but the risk of RAO should be noted, particularly in patients with small radial artery diameters. This study suggests a radial artery diameter cutoff value of 2.4 mm to predict RAO, aiding access decisions for large-bore BGC. Further multicenter prospective studies are warranted to confirm these findings and assess long-term outcomes.

Indexed as

Feasibility StudiesRadial ArteryAgedAged, 80 and overArterial Occlusive DiseasesEndovascular ProceduresFemaleHumansMaleMiddle AgedRetrospective StudiesBalloon guide catheterDistal transradial accessNeuroendovascular procedureRadial artery diameterRadial artery occlusionSheathless access

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.