Advancing the design of interspinous fixation devices for improved biomechanical performance: dual

Kingsley R Chin, Vito Lore, Erik Spayde, William M Costigan, Zoha Irfan, Owen Battel, Deepak K Pandey, Chukwunonso C Ilogu, Jason A Seale

Abstract read
In one paragraph

Article in Journal of spine surgery (Hong Kong), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Revision surgical technique for laterally placed MinuteManJournal of spine surgery (Hong Kong) · 2026
    Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Kingsley R ChinLess Exposure Spine Surgery Institute (LESS Institute aka LESS Clinic), Hollywood, FL, USA.
Vito LoreLESSpine, Burlington, MA, USA.
Erik SpaydeSt. Charles Spine Institute, Thousand Oaks, CA, USA.
William M CostiganCongress Orthopaedic Associates, Pasadena, CA, USA.
Zoha IrfanDepartment of Orthopedics, Herbert Wertheim College of Medicine at Florida International University, Miami, FL, USA.
Owen BattelDepartment of Orthopedics, Herbert Wertheim College of Medicine at Florida International University, Miami, FL, USA.
Deepak K PandeyLess Exposure Spine Surgery (LESS) Society 501©(3), Hollywood, FL, USA.
Chukwunonso C IloguLess Exposure Spine Surgery Institute (LESS Institute aka LESS Clinic), Hollywood, FL, USA.
Jason A SealeLess Exposure Spine Surgery Institute (LESS Institute aka LESS Clinic), Hollywood, FL, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Interspinous devices were introduced in the field of spine surgery as an alternative to traditional pedicle screw fixation in selected patients for treatment of spinal stenosis and fixation. These devices designs have evolved from non-fixated extension blocks to sophisticated interspinous fixation devices (IFDs). There is an absence of literature comparing the biomechanical fixation strength of different IFD plate designs and the role of set screw locking systems. The aim of this study was to evaluate fixation strengths by bench testing static disassembly and pullout strength of two dissimilar IFD designs and locking mechanisms. We hypothesized that the InSpan (InSpan LLC, Burlington, MA, USA) dual-locking symmetrically IFD plate designed will have stronger fixation than the Aspen (ZimVie, Parsippany, NJ, USA) single-locking asymmetric IFD plate design. Methods: We conducted two biomechanical bench tests to evaluate the load to failure locking characteristics of symmetrical InSpan and asymmetrical Aspen IFD designs. Static pullout testing involved locking each IFD to the stainless steel and 40 pcf cellular polyurethane foam and measuring pullout load and displacement six times. Seven InSpan and two Aspen IFDs (including the "used" IFDs from the pullout testing) underwent static disassembly tests using a pair of disassembly fixtures positioned between the IFD plates to measure disassembly force and displacement. All tests were performed under ambient conditions using an INSTRON 8874 Bi-Axial Tabletop Servohydraulic Dynamic Testing System (INSTRON, Norwood, MA, USA), and data was collected at a 0.2 mm/s displacement control rate until the test was stopped when there was a drop in the continuously increasing force against resistance (gross failure). Results: The InSpan IFD experienced 94.81% higher resistance to pullout compared to the Aspen IFD in static pullout testing (P<0.05), owing to its notably larger footprint area of 69.8%. Gross failure for both IFD implant designs occurred at the foam block-block interface. In static disassembly testing, pristine InSpan required 60.7% higher force over pristine Aspen and 401.3% for "used" IFDs. Gross failure was characterized by the gradual distraction of the plates and material removal at the set screw contact points. Implant failure at the block-implant interface emphasized the pivotal role of teeth design and the contact surface area of the plates in ensuring stability. Conclusions: The dual-locking symmetrical InSpan IFD outperformed single-locking asymmetric Aspen IFD in both static disassembly and pullout bench tests. This highlights the benefits of InSpan's improved design and its potential for enhanced long-term stability in spinal fixation applications.

Indexed as

fusionInSpan interspinous fixation device (InSpan IFD)interspinouspedicle screwsstenosis

Identifiers

PMID39399071
PMCPMC11467278

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.