Evidence map›Paper›PMID 39397350›Full record

ArticleJournal of medical radiation sciences2025

Intrafraction motion and impact of margin reduction for MR-Linac online adaptive radiotherapy for pancreatic cancer treatments.

Ashleigh Fasala, Madeline Carr, Yolanda Surjan, Parmoun Daghigh, Jeremy de Leon, Abbey Burns, Vikneswary Batumalai

Abstract read
In one paragraph

Article in Journal of medical radiation sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ashleigh FasalaGenesisCare, Sydney, New South Wales, Australia.
Madeline CarrGenesisCare, Sydney, New South Wales, Australia.
Yolanda SurjanCollege of Health, Medicine and Wellbeing, School of Health Sciences, Global Centre for Research and Training in Radiation Oncology, The University of Newcastle, Callaghan, New South Wales, Australia.
Parmoun DaghighSchool of Physics, University of Sydney, Sydney, New South Wales, Australia.
Jeremy de LeonGenesisCare, Sydney, New South Wales, Australia.
Abbey BurnsGenesisCare, Sydney, New South Wales, Australia.
Vikneswary BatumalaiGenesisCare, Sydney, New South Wales, Australia.ORCID https://orcid.org/0000-0003-2021-2599

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionOnline adaptive radiotherapy is well suited for stereotactic ablative radiotherapy (SABR) in pancreatic cancer due to considerable intrafractional tumour motion. This study aimed to assess intrafraction motion and generate adjusted planning target volume (PTV) margins required for online adaptive radiotherapy in pancreatic cancer treatment using abdominal compression on the magnetic resonance linear accelerator (MR-Linac).

methodsMotion monitoring images obtained from 67 fractions for 15 previously treated pancreatic cancer patients were analysed. All patients received SABR (50 Gy in five fractions) on the MR-Linac using abdominal compression. The analysis included quantification of intrafraction motion, leading to the development of adjusted PTV margins. The dosimetric impact of implementing the adjusted PTV was then evaluated in a cohort of 20 patients.

resultsIntrafraction motion indicated an average target displacement of 1-3 mm, resulting in an adjusted PTV margin of 2 mm in the right-left and superior-inferior directions, and 3 mm in the anterior-posterior direction. Plans incorporating these adjusted margins consistently demonstrated improved dose to target volumes, with improvements averaging 1.5 Gy in CTV D99%, 4.9 Gy in PTV D99% and 1.2 Gy in PTV-high D90%, and better sparing of the organs at risk (OAR).

conclusionsThe improved target volume coverage and reduced OAR dose suggest potential for reducing current clinical margins for MR-Linac treatment. However, it is important to note that decreasing margins may reduce safeguards against geographical misses. Nonetheless, the continued integration of gating systems on MR-Linacs could provide confidence in adopting reduced margins.

Indexed as

Dose Fractionation, RadiationMagnetic Resonance ImagingPancreatic NeoplasmsParticle AcceleratorsRadiosurgeryFemaleHumansMaleMiddle AgedMovementRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedAbdominal compressionintrafraction motionmargin reductionMR‐Linacpancreatic cancerstereotactic ablative body radiotherapy

Identifiers

PMID39397350
PMCPMC11909694

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.