Evidence map›Paper›PMID 39395998›Full record

ArticleJournal of orthopaedic surgery and research2024

Are all robotic technologies created equal? Comparing one of the latest image-free robotic technologies to all other robotic systems for total knee arthroplasty.

Philip Huang, Michael Cross, Anshu Gupta, Dhara Intwala, Jill Ruppenkamp, Daniel Hoeffel

Abstract readComparative Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Philip HuangOrthoIndy, Indianapolis, IN, USA.
Michael CrossOrthoIndy, Indianapolis, IN, USA.
Anshu GuptaEpidemiology & Real-World Data Sciences, Johnson & Johnson MedTech, New Brunswick, NJ, USA. agupta67@its.jnj.com.
Dhara IntwalaDePuy Synthes Digital, Robotics & Emerging Channels, Raynham, MA, USA.
Jill RuppenkampEpidemiology & Real-World Data Sciences, Johnson & Johnson MedTech, New Brunswick, NJ, USA.
Daniel HoeffelDePuy Synthes, Medical Affairs, Palm Beach Gardens, FL, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRobotic-assisted technologies have been developed to increase surgical precision and reduce surgical variability in total knee arthroplasty (TKA). Several different robotic systems have been introduced in the last decade for TKA. The DePuy Synthes VELYS™ Robotic-Assisted Solution (VRAS) is an imageless system designed to eliminate the need for preoperative CT scans and is one of the latest entrants in the rapidly evolving field of robotic technology in TKA. This study compared the clinical and economic outcomes associated with VRAS and other robotic-assisted technologies for primary TKA.

methodsA retrospective cohort study using the Premier Healthcare Database included patients who underwent primary TKA with VRAS or other robotic-assisted technologies from January 1, 2022, to April 30, 2023. The primary outcome for the study was hospital follow-up visits (revisits) within 90 days post-TKA. Secondary outcomes included readmission and revision rates within 90 days post-TKA, operating room time, length of stay, discharge status and hospital costs. Cohorts were balanced using propensity score fine stratification, and generalized linear models were constructed to evaluate outcomes.

resultsThis study included 827 VRAS TKA patients and 16,428 TKA patients treated with other robotic-assisted technologies. The 90-day all-cause and knee-related revisit rates were significantly lower for VRAS than for other robotic-assisted technologies (all-cause 13.9% vs. 22.8% and knee-related 2.8% vs. 5.4%, respectively; p value < 0.01). The all-cause and knee-related 90-day readmission rates were also lower for VRAS, although the differences were not statistically significant. The 90-day revision rates were similar for VRAS and other robotic-assisted technologies (0.48% vs. 0.45%), as was the operating room time (138 vs. 137 min). The 90-day knee-related cost for the VRAS cohort was $15,048 compared to $16,867 for other robotic technologies.

conclusionsThis database study demonstrated that early postoperative revisit rates and total cost of care are lower for VRAS than for all other robotic-assisted technologies for TKA, while operating room time and discharge status were similar. These are important findings in ever-evolving healthcare systems that are increasingly cost conscious and cognizant of principles associated with value-based care.

Indexed as

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresAgedAged, 80 and overCohort StudiesFemaleHumansLength of StayMaleMiddle AgedOperative TimePatient ReadmissionRetrospective StudiesTreatment OutcomeCostReadmissionRevisionRobotic surgeryTotal knee arthroplastyVELYSVRAS

Identifiers

PMID39395998
PMCPMC11470650

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.