ArticleJournal of orthopaedic surgery and research2024
Are all robotic technologies created equal? Comparing one of the latest image-free robotic technologies to all other robotic systems for total knee arthroplasty.
Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Use of the VELYS Robotic-Assisted Solution in knee arthroplasty: A scoping review.Journal of experimental orthopaedics · 2026Review
- Article
- Applications of robotic technology in orthopaedic surgery: A technology review.Journal of robotic surgery · 2025Review
- Evolutionary patterns and future perspectives of joint replacement in arthritis patients: a comprehensive analysis of findings over the past decades.EFORT open reviews · 2025Article
- Short learning curve associated with robotic total knee arthroplasty: A retrospective study.Journal of experimental orthopaedics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundRobotic-assisted technologies have been developed to increase surgical precision and reduce surgical variability in total knee arthroplasty (TKA). Several different robotic systems have been introduced in the last decade for TKA. The DePuy Synthes VELYS™ Robotic-Assisted Solution (VRAS) is an imageless system designed to eliminate the need for preoperative CT scans and is one of the latest entrants in the rapidly evolving field of robotic technology in TKA. This study compared the clinical and economic outcomes associated with VRAS and other robotic-assisted technologies for primary TKA.
methodsA retrospective cohort study using the Premier Healthcare Database included patients who underwent primary TKA with VRAS or other robotic-assisted technologies from January 1, 2022, to April 30, 2023. The primary outcome for the study was hospital follow-up visits (revisits) within 90 days post-TKA. Secondary outcomes included readmission and revision rates within 90 days post-TKA, operating room time, length of stay, discharge status and hospital costs. Cohorts were balanced using propensity score fine stratification, and generalized linear models were constructed to evaluate outcomes.
resultsThis study included 827 VRAS TKA patients and 16,428 TKA patients treated with other robotic-assisted technologies. The 90-day all-cause and knee-related revisit rates were significantly lower for VRAS than for other robotic-assisted technologies (all-cause 13.9% vs. 22.8% and knee-related 2.8% vs. 5.4%, respectively; p value < 0.01). The all-cause and knee-related 90-day readmission rates were also lower for VRAS, although the differences were not statistically significant. The 90-day revision rates were similar for VRAS and other robotic-assisted technologies (0.48% vs. 0.45%), as was the operating room time (138 vs. 137 min). The 90-day knee-related cost for the VRAS cohort was $15,048 compared to $16,867 for other robotic technologies.
conclusionsThis database study demonstrated that early postoperative revisit rates and total cost of care are lower for VRAS than for all other robotic-assisted technologies for TKA, while operating room time and discharge status were similar. These are important findings in ever-evolving healthcare systems that are increasingly cost conscious and cognizant of principles associated with value-based care.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials