Evidence map›Paper›PMID 39392408›Full record

ArticleActa orthopaedica2024

Are some neutral liners more neutral than others? An ex vivo morphological analysis of acetabular liners classified as "neutral".

José Á Ochoa, Perttu S Neuvonen, Jari Hyttinen, Jari Viik, Antti P Eskelinen

Abstract read
In one paragraph

Article in Acta orthopaedica, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

José Á OchoaFaculty of Medicine and Health Technology, Tampere University, Tampere, Finland.ORCID 0000-0003-0367-3182
Perttu S NeuvonenFaculty of Medicine and Health Technology, Tampere University, Tampere; Coxa Hospital for Joint Replacement, Tampere, Finland. perttu.neuvonen@coxa.fi.ORCID 0000-0002-6921-8134
Jari HyttinenFaculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
Jari ViikFaculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
Antti P EskelinenFaculty of Medicine and Health Technology, Tampere University, Tampere; Coxa Hospital for Joint Replacement, Tampere, Finland.ORCID 0000-0003-0302-0253

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeIn contemporary total hip replacement (THR), dislocation is one of the most common complications. At our institution, the cause of an increase in the dislocation rate was recently reported to be reduced head coverage of a newly introduced neutral liner. We therefore aimed to ascertain whether differences exist in articulating head coverage between the various neutral liners used in contemporary THR. A secondary aim was to utilize coverage measurements to develop a new liner coverage classification.

methodsThe articulating head coverage of 25 modular neutral polyethylene liners used in 6 uncemented cup designs from 4 major manufacturers was evaluated. The measurements were performed in a metrology laboratory and a mathematical model was developed to calculate coverage of the articulating surfaces. Further, 1 "elevated rim" liner and 1 "face changing liner" were included to develop a new liner coverage classification.

resultsThe articulating head coverage among the studied liners ranged from 167.7° to 194.8°, corresponding to a variation of 27.1°. The variations with different cup and head sizes within each design were smaller (from 1.0° to 5.6°) than those between different designs. Each of the liner designs offered distinct coverage, even though they were all classified as neutral. Based on measurements, a set of descriptive parameters to discriminate different liners in terms of coverage was created.

conclusionWe showed that all neutral liners are not equal - instead, they clearly varied in terms of their actual coverage design. We suggest our set of descriptive parameters called "hemispheric coverage index values" be used in discriminating the differences in liner coverage.

Indexed as

AcetabulumArthroplasty, Replacement, HipHip ProsthesisProsthesis DesignHip DislocationHumansMaterials TestingPolyethyleneProsthesis FailurePolyethylene

Identifiers

PMID39392408
PMCPMC11468231

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.