Evidence map›Paper›PMID 39390285›Full record

ArticleThe Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology2024

Utility of the AngelMed Guardian System in myocardial bridging: a case report.

Lakshmi Rao, Arjun Chadha, Anila Rao, Anurag Khandavalli, Surya Rao

Abstract read
In one paragraph

Article in The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lakshmi RaoMcLaren Macomb Medical Center, 1000 Harrington St, Mount Clemens, MI, 48043, USA.
Arjun ChadhaMcLaren Macomb Medical Center, 1000 Harrington St, Mount Clemens, MI, 48043, USA. arjun.chadha@mclaren.org.ORCID http://orcid.org/0000-0003-3829-0800
Anila RaoMcLaren Macomb Medical Center, 1000 Harrington St, Mount Clemens, MI, 48043, USA.
Anurag KhandavalliMcLaren Macomb Medical Center, 1000 Harrington St, Mount Clemens, MI, 48043, USA.
Surya RaoAdventHealth Cardiovascular Institute, Port Orange, FL, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMyocardial bridging (MB) is a known congenital anomaly in which a segment of the coronary artery transverses from the epicardium through the myocardium. MB may clinically manifest as recurrent angina, acute coronary syndrome, ventricular dysrhythmia, and even sudden cardiac death. On electrocardiogram (EKG), MB can present with findings consistent with significant ST-segment changes. The AngelMed Guardian System (the Guardian device) was developed in an effort to optimize the time from the onset of myocardial ischemia to intervention. The device analyzes myocardial electrical changes and alerts the patient to seek emergent medical evaluation if an acute ST-segment deviation is detected. We describe the first documented case of the Guardian device detecting acute ST-segment changes secondary to myocardial bridging. CASE PRESENTATION: A 50-year-old male, with a history of percutaneous coronary intervention of the proximal left anterior descending (LAD) artery, presented to his cardiologist's office with reports of recurrent, atypical chest pain. The Guardian device was implanted. One month after implantation, the patient experienced chest pain and was alerted by the Guardian device to seek emergent medical evaluation. Initial EKG and high-sensitivity troponins were negative for acute ischemia. Guardian device interrogation revealed significant ST depressions, encouraging further ischemic evaluation. The exercise myocardial perfusion imaging revealed an apical reversible defect. Left heart catheterization revealed a large segment of mid-LAD MB with the patient's previous LAD stent noted to be widely patent along with no evidence of new obstructive coronary disease. Following the identification of the MB, medication regimen adjusted and the patient denied recurrence of chest pain or Guardian alerts.

conclusionsWe describe the first documented case of the Guardian device detecting acute ST-segment changes that were secondary to myocardial bridging. The Guardian device appropriately documented an ischemic event not appreciated with initial EKG or troponin testing. With the assistance of the Guardian device, we were able to rapidly identify MB as the cause for the ischemic EKG changes and subsequent abnormal stress test, optimize medical management, and prevent recurrent atypical chest pain along with office and hospital visits.

Indexed as

AngelMed Guardian SystemGuardian deviceMyocardial bridging

Identifiers

PMID39390285
PMCPMC11466916

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.