Observational studyJournal of clinical monitoring and computing2025
Clinical evaluation of a smart wristband for monitoring oxygen saturation, pulse rate, and respiratory rate.
Observational study in Journal of clinical monitoring and computing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Multi Parameter Vital Signs Monitoring by the Corsano CardioWatch 287-2 Validation Study
Health Behaviour Change, Education on Risk Factor Reduction, Physical Activity Guidance, and Nutrition Counselling With a Remote Team to Support Patient Progress Using Technology in Synchronization With Medication Management and CardioWatch 287-2. (HEARTS in Sync + CardioWatch 287-2)
Who cites it
8 citing papers in PubMed.
- Multimodal Wearable and Survey Data Reveal Distinct Physiologic Profiles in Hypermobile-Ehlers Danlos Syndrome for Screening Advancements.medRxiv : the preprint server for health sciences · 2026Article
- Accuracy of vital sign monitoring using a photoplethysmography upper arm wearable device in postoperative non-cardiac surgery patients: a prospective observational clinical validation study.Journal of clinical monitoring and computing · 2026Observational
- Continuous Vital Signs Monitoring with a Wireless and Wearable Earsensor in Surgical Patients: A Clinical Validation Study.Sensors (Basel, Switzerland) · 2026Observational
- Continuous remote monitoring of postoperative vital signs with the Biobeat patch: A multicenter prospective observational study.PloS one · 2026Observational
- Wearable Devices in Healthcare Beyond the One-Size-Fits All Paradigm.Sensors (Basel, Switzerland) · 2025Review
- Reliability of an all-in-one wearable sensor for continuous vital signs monitoring in high-risk patients: the NIGHTINGALE clinical validation study.Journal of clinical monitoring and computing · 2025Observational
- Continuous monitoring of critically ill patients using photoplethysmography-the road to a less invasive ICU monitoring.Frontiers in digital health · 2025Article
- Evaluation of Photoplethysmography-Based Monitoring of Respiration Rate During High-Intensity Interval Training: Implications for Healthcare Monitoring.Biosensors · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Recently, photoplethysmography-based vital parameter measurements have increased in popularity. However, clinical evaluation of these measurements is lacking. The objective of this study was to rigorously evaluate the clinical accuracy and reliability of a novel photoplethysmography-based wristband for measuring key vital parameters-oxygen saturation (SpO2), respiratory rate (RR), and pulse rate (PR)-during heart catheterisations. Vital parameters obtained during heart catheterisations by means of a photoplethysmography-based wristband (CardioWatch 287-2, Corsano Health) were compared to reference measurements performed by a Nellcor fingerclip (SpO2, PR) as well as a 5-lead ECG (RR) (QMAPP Haemodynamic Monitoring module, Fysicon B.V.) by means of correlation coefficients and root means squared error (RMSE). Effects of skin colour and arm hair density were additionally evaluated. In total, 945 samples from a total of 100 patients were included in the analysis. The correlation coefficients and RSME obtained for the difference between reference and photoplethysmography-based wristband measurements were r = 0.815 and 1.6% for SpO2, r = 0.976 and 0.9 brpm for RR, and r = 0.995 and 1.3 bpm for PR. Similar results were obtained across all skin colour and arm hair density subcategories. This study shows that photoplethysmography-based SpO2, RR, and PR measurements can be accurate during heart catheterisations. Future investigations are required to evaluate the wristband's performance under dynamic circumstances as well as over an extended time period. Trial registration: www.clinicaltrials.gov, NCT05566886.
Indexed as
Identifiers
39388061What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.