Evidence map›Paper›PMID 39386417›Full record

ReviewJournal of orthopaedics2025

Far cortical locking versus standard locking screw fixation in simulated femoral fractures: A biomechanical meta-analysis.

Robert S Bullock, John G Coury, Brendan Liakos, Eric G Huish

Abstract readReview
In one paragraph

Review in Journal of orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Finite element andFrontiers in bioengineering and biotechnology · 2026
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Robert S BullockValley Consortium for Medical Education, 1400 Florida Ave Suite 200, Modesto, CA, 95350, USA.
John G CouryValley Consortium for Medical Education, 1400 Florida Ave Suite 200, Modesto, CA, 95350, USA.
Brendan LiakosValley Consortium for Medical Education, 1400 Florida Ave Suite 200, Modesto, CA, 95350, USA.
Eric G HuishValley Consortium for Medical Education, 1400 Florida Ave Suite 200, Modesto, CA, 95350, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Far cortical locking (FCL) is a concept of locking plate fixation with reduced stiffness and symmetric micromotion to improve callus formation. The goal of our study was to review biomechanical data evaluating FCL plate and screw fixation versus standard locking (SL) plate and screw fixation by analyzing studies of cadaveric and synthetic bone models to draw biomechanical conclusions. Methods: Biomechanical studies that compared FCL and SL plate fixation for simulated femoral fractures were reviewed for construct stiffness, load to failure, axial motion at the near and far cortices, and the difference between near and far cortical axial motion to demonstrate motion symmetry. Results: FCL decreased stiffness by 1.069 kN/mm compared to SL (95 % CI 0.405 to 1.732, p = 0.002). FCL demonstrated greater axial motion than SL in the near cortex by 0.425 mm (95 % CI 0.359 to 0.491, p < 0.001) and in the far cortex by 0.456 mm (95 % CI 0.378 to 0.534, p < 0.001). FCL resulted in symmetric motion with no significant difference between far and near cortices with the far cortex displacing 0.347 mm more than near (95 % CI -0.038 to 0.731, p = 0.78). SL resulted in asymmetric motion favoring the far cortex by 0.270 mm (0.096-0.443, p = 0.002). Construct strength was not significantly different with FCL load to failure 0.367 kN greater than SL (95 % CI -0.762 to 1.496, p = 0.524). Conclusion: FCL screw fixation in femoral fractures achieves the goals of reducing construct stiffness and promoting more symmetric axial motion while maintaining construct strength. These results support the overall biomechanical goals of far cortical locking and should encourage investigation into its effects on clinical and radiographic outcomes.

Indexed as

BiomechanicalDistal femurFar cortical lockingNonunionSupracondylar femur

Identifiers

PMID39386417
PMCPMC11460246

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.