ArticleMedical physics2024
Design, construction, and use of a tapered-spiral, quadrature
Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Design, construction, and use of a tapered-spiral, quadratureMedical physics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIn ovo MR presents a promising and viable alternative to traditional in vivo small animal experiments. Sodium MRI complements proton MRI by providing potential access to tissue cellular metabolism. Despite its abundance, sodium MRI is challenged by lower MR sensitivity and faster relaxation times compared to proton MRI. Ensuring a high signal-to-noise ratio and effective B PURPOSE: This study introduces a novel, highly optimized, double-tuned coil design, specifically for MR scans of chick embryos.
methodsA tapered-spiral, double-tuned coil was designed and constructed following careful consideration of design parameters. The performance of the coil was rigorously assessed through bench tests, and final validation was conducted on a 7 T MRI scanner using a chick embryo.
resultsBench tests demonstrated that the return losses for both
conclusionsThe innovative design of the proposed double-tuned coil, characterized by its unique arrangement, offers improved performance. This design has the potential to significantly enhance the quality of in ovo
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.