Evidence map›Paper›PMID 39382738›Full record

ArticleEuropean radiology experimental2024

Validation of a multi-parameter algorithm for personalized contrast injection protocol in liver CT.

Hugues G Brat, Benoit Dufour, Natalie Heracleous, Pauline Sastre, Cyril Thouly, Benoit Rizk, Federica Zanca

Abstract readValidation StudyMulticenter Study
In one paragraph

Article in European radiology experimental, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hugues G BratInstitut de Radiologie de Sion, Groupe 3R, Sion, Switzerland.
Benoit DufourInstitut de Radiologie de Sion, Groupe 3R, Sion, Switzerland.
Natalie HeracleousInstitut de Radiologie de Sion, Groupe 3R, Sion, Switzerland.
Pauline SastreGE Healthcare, Buc, France.
Cyril ThoulyInstitut de Radiologie de Sion, Groupe 3R, Sion, Switzerland.
Benoit RizkCentre d'Imagerie de Fribourg, Groupe 3R, Fribourg, Switzerland.
Federica ZancaInstitut de Radiologie de Sion, Groupe 3R, Sion, Switzerland. federica.zanca@palindromo.consulting.ORCID http://orcid.org/0000-0001-9340-5098

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn liver computed tomography (CT), tailoring the contrast injection to the patient's specific characteristics is relevant for optimal imaging and patient safety. We evaluated a novel algorithm engineered for personalized contrast injection to achieve reproducible liver enhancement centered on 50 HU.

methodsFrom September 2020 to August 31, 2022, CT data from consecutive adult patients were prospectively collected at our multicenter premises. Inclusion criteria consisted of an abdominal CT referral for cancer staging or follow-up. For all examinations, a web interface incorporating data from the radiology information system (patient details and examination information) and radiographer-inputted data (patient fat-free mass, imaging center, kVp, contrast agent details, and imaging phase) were used. Calculated contrast volume and injection rate were manually entered into the CT console controlling the injector. Iopamidol 370 mgI/mL or Iohexol 350 mgI/mL were used, and kVp varied (80, 100, or 120) based on patient habitus.

resultsWe enrolled 384 patients (mean age 61.2 years, range 21.1-94.5). The amount of administered iodine dose (gI) was not significantly different across contrast agents (p = 0.700), while a significant increase in iodine dose was observed with increasing kVp (p < 0.001) and in males versus females (p < 0.001), as expected. Despite the differences in administered iodine load, image quality was reproducible across patients with 72.1% of the examinations falling within the desirable range of 40-60 HU.

conclusionThis study validated a novel algorithm for personalized contrast injection in adult abdominal CT, achieving consistent liver enhancement centered at 50 HU. RELEVANCE STATEMENT: In healthcare's ongoing shift towards personalized medicine, the algorithm offers excellent potential to improve diagnostic accuracy and patient management, particularly for the detection and follow-up of liver malignancies. KEY POINTS: The algorithm achieves reproducible liver enhancement, promising improved diagnostic accuracy and patient management in diverse clinical settings. The real-world study demonstrates this algorithm's adaptability to different variables ensuring high-quality liver imaging. A personalized algorithm optimizes liver CT, improving the visibility, conspicuity, and follow-up of liver lesions.

Indexed as

AlgorithmsContrast MediaTomography, X-Ray ComputedAdultAgedAged, 80 and overFemaleHumansIohexolIopamidolLiverLiver NeoplasmsMaleMiddle AgedProspective StudiesYoung AdultContrast MediaIohexolIopamidolAbdomenBody compositionContrast mediaLiverMultidetector computed tomography

Identifiers

PMID39382738
PMCPMC11465069

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.