ArticleCVIR endovascular2024
Protrieve Sheath embolic protection during venous thrombectomy: early experience in seventeen patients.
Article in CVIR endovascular, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- The ProTrieve Sheath funnel captures embolized filter fragments during complex inferior vena cava filter removal.Journal of vascular surgery cases and innovative techniques · 2026Article
- RevCore thrombectomy device effectively restores venous stent patency by treating iliofemoral caval in-stent restenosis.Journal of vascular surgery cases and innovative techniques · 2025Article
- Venous thrombectomy using the InThrill Thrombectomy System: preliminary experiences.CVIR endovascular · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe Protrieve Sheath (Inari Medical; Irvine, CA) is designed for embolic protection during venous thrombectomy. This report describes experience with its use. MATERIALS AND
methodsBetween November 2022 and December 2023 (13 months), seventeen patients, including nine (52.9%) females and eight (47.1%) males (mean age 58.8 ± 13.3 years, range 37-81 years), underwent deep venous thrombectomy following the Protrieve Sheath placement for embolic protection. Gender, age, presenting symptoms, procedural indications, obstructed venous segments, the Protrieve Sheath access and deployment sites, thrombectomy devices utilized, need for stent reconstruction, technical success, clinical success, adverse events (the Protrieve Sheath maldeployment or clinically significant embolic events), removed thrombi analyses, and mortality were recorded. Technical success was defined as successful deployment of the Protrieve Sheath funnel central to the thrombectomy site. Clinical success was defined as improvement in presenting venous occlusive symptoms without procedure-related venous thromboembolism.
resultsThe most common presenting symptom was extremity swelling (n = 15; 88.2%). Nine (52.9%) patients had malignant and eight (47.1%) had benign etiologies of venous obstruction. Obstructed venous segments included the inferior vena cava (IVC) and lower extremity (n = 9; 52.9%), isolated lower extremity (n = 4; 23.5%), isolated IVC (n = 2; 11.8%), thoracic central veins and superior vena cava (n = 1; 5.9%), and isolated thoracic central vein (n = 1; 5.9%). The Protrieve Sheath access sites included the right internal jugular vein (n = 15; 88.2%) for IVC and lower extremity obstructions and the right common femoral vein (n = 2; 11.8%) for thoracic central vein and superior vena cava obstructions. The Protrieve sheath funnel deployment locations included intrahepatic IVC in 13 patients (n = 13; 76.5%), suprarenal IVC in two (n = 2; 11.8%), and inferior cavoatrial junction in two (n = 2; 11.8%). Thrombectomy devices used included the ClotTriever System (Inari Medical) (n = 15; 88.2%), the InThrill Thrombectomy System (Inari Medical) (n = 4; 23.5%), the FlowTriever System (Inari Medical) (n = 2; 11.8%), the Lightning Flash 16 Aspiration System (Penumbra; Salt Lake City, UT) (n = 2; 11.8%), the Cleaner Rotational Thrombectomy System (Argon; Plano, TX) (n = 1; 5.9%), and the RevCore Thrombectomy System (Inari Medical) (n = 1; 5.9%). Ten (58.8%) patients required stent reconstruction following thrombectomy. Technical success was achieved in all patients. Clinical success was achieved in 16 (94.1%) patients. No immediate adverse events, including the Protrieve Sheath maldeployment or clinically significant embolic events, occurred.
conclusionUse of the Protrieve Sheath during large-bore venous mechanical thrombectomy resulted in favorable technical and clinical outcomes without device-related adverse events or clinically significant thromboembolic events.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.