Evidence map›Paper›PMID 39382624›Full record

ArticleInsights into imaging2024

Assessment of the supraspinatus muscle fiber architecture with diffusion tensor imaging in healthy volunteers.

Adrian Alexander Marth, Stefan Sommer, Georg Wilhelm Kajdi, Sophia Samira Goller, Thorsten Feiweier, Reto Sutter, Daniel Nanz, Constantin von Deuster

Abstract read
In one paragraph

Article in Insights into imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Adrian Alexander MarthSwiss Center for Musculoskeletal Imaging, Balgrist Campus AG, Zurich, Switzerland. adrian.marth@balgristcampus.ch.ORCID http://orcid.org/0000-0002-7334-0757
Stefan SommerSwiss Center for Musculoskeletal Imaging, Balgrist Campus AG, Zurich, Switzerland.
Georg Wilhelm KajdiDepartment of Radiology, Balgrist University Hospital, Zurich, Switzerland.
Sophia Samira GollerDepartment of Radiology, Balgrist University Hospital, Zurich, Switzerland.
Thorsten FeiweierSiemens Healthineers AG, Erlangen, Germany.
Reto SutterDepartment of Radiology, Balgrist University Hospital, Zurich, Switzerland.
Daniel NanzSwiss Center for Musculoskeletal Imaging, Balgrist Campus AG, Zurich, Switzerland.
Constantin von DeusterSwiss Center for Musculoskeletal Imaging, Balgrist Campus AG, Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study presents a framework for the calculation of supraspinatus (SSP) muscle pennation angles (PAs) from diffusion tensor imaging (DTI). MATERIALS AND

methodsTen healthy individuals (five females and five males; age 32.0 ± 4.7 years) underwent three sessions of 3-T MRI, including a stimulated echo acquisition mode DTI sequence. The imaging plane of the DTI sequence was angled along the intramuscular part of the SSP tendon. A custom-built software was developed and implemented to compute DTI-based PAs of the anterior and posterior SSP in relation to the orientation of the tendon. Subsequently, three readers measured PAs from the post-processed images. Test-retest reliability, inter-reader agreement, and intra-reader agreement of PA measurements were evaluated with intraclass correlation coefficients (ICCs).

resultsThe mean PA in the anterior SSP was 15.6 ± 2.1° and 10.7 ± 0.9° in the posterior SSP. MRI-derived PAs showed good to excellent test-retest reliability (ICC: 0.856-0.945), inter-reader agreement (ICC: 0.863-0.955), and intra-reader agreement (ICC: 0.804-0.955).

conclusionPAs derived from DTI demonstrated good to excellent test-retest reliability, inter-reader agreement, and intra-reader agreement. We successfully implemented a highly standardized technique for evaluating PAs of the SSP muscle. CRITICAL RELEVANCE STATEMENT: This proposed low-complex method might facilitate the increased use of the PA as a biomarker for pathological conditions of the rotator cuff. KEY POINTS: A low-complex method for measuring PAs of the SSP might help identify pathology early. The mean PA was 15.6 ± 2.1° and 10.7 ± 0.9° in the anterior and posterior SSP, respectively. ICCs were ≥ 0.856 for test-retest reliability, ≥ 0.863 for inter-reader agreement, and ≥ 0.804 for intra-reader agreement.

Indexed as

Diffusion tensor imagingMyoarchitecturePennation angleRotator cuff

Identifiers

PMID39382624
PMCPMC11464712

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.